The HumaPen MEMOIR

®

 is designed to reliably deliver an accurate dose of your insulin and 

for ease of use. You can inject from 1 to 60 units of any HuMalOg

®

 or HuMulIn

®

 insulin 

from a 3 ml cartridge (100 units/ml). You can dial your dose one unit at a time. If you dial 

too many units, you can correct the dose without wasting any insulin. HumaPen MEMOIR has 

a dose memory that allows you to see the time, date and amount of the last 16 doses that 

were delivered including the priming doses.

Le stylo HumaPen MEMOIR est conçu pour permettre l’injection d’une dose exacte 

d’insuline de façon simple et fiable. Vous pouvez injecter de 1 à 60 unités d’insuline 

HuMaLOg ou HuMuLIn d’une cartouche de 3 mL (100 unités/mL). Vous pouvez 

sélectionner la dose une unité à la fois. Si vous choisissez plus d’unités qu’il ne vous 

en faut, vous pouvez corriger la dose sans gaspiller d’insuline. HumaPen MEMOIR a une 

mémoire de dose qui permet d’afficher la date, l’heure et la quantité des 16 dernières 

doses, y compris les doses d’amorçage du stylo.

ImPoRTaNT NoTES / REmaRQUES ImPORTaNTES

SETTINg TImE aND DaTE / RÉgLagE DE La DaTE ET DE L’HEURE

LoaDINg a CaRTRIDgE / CHaRgEmENT D’UNE CaRTOUCHE

PREPaRINg aND PRImINg YoUR PEN / PRÉPaRaTION ET amORÇagE DU STYLO

SETTINg aND INJECTINg YoUR INSULIN DoSE / SÉLECTION ET INJECTION DE La DOSE D’INSULINE

CHaNgINg INSULIN CaRTRIDgE / CHaNgEmENT DE La CaRTOUCHE D’INSULINE

FINISHINg aN INComPLETE DoSE / INJECTION DU RESTE D’UNE DOSE INCOmPLÈTE

VIEWINg DoSE mEmoRY / LECTURE DE La mÉmOIRE DE DOSE

DISPLaY mESSagES aND ERRoRS / 

 aFFICHagE DES mESSagES ET DES ERREURS

CaRE, SToRagE aND DISPoSaL / ENTRETIEN, CONSERVaTION ET ÉLImINaTION

Fold out to see PEN PaRTS diagram 

Dépliez pour voir le diagramme des PIÈCES DU STYLO 

Guide de l’utilisateur 

Read this entire manual completely and follow the directions carefully before 

using your new HumaPen mEmoIR.

 Failure to follow the instructions may result in 

too much or too little insulin being delivered.

Do NoT SHaRE YoUR PEN oR NEEDLES aS THIS maY RISK TRaNSmISSIoN oF 

INFECTIoUS agENTS.

If any of the parts of your HumaPen MEMOIR appear broken or damaged, 

do NoT use. 

Contact your healthcare professional or call lilly at 1-888-545-5972 for assistance.

avant d’utiliser votre nouveau stylo HumaPen mEmOIR, assurez-vous de lire au 

complet ce guide et de suivre attentivement les directives. 

L’inobservation des 

instructions peut entraîner l’injection d’une dose inexacte d’insuline. 

NE PaRTagEZ PaS VOTRE STYLO NI VOS aIgUILLES; LE FaIRE POURRaIT 

ENTRaÎNER La TRaNSmISSION D’agENTS INFECTIEUX.

N’UTILISEZ PaS

 le stylo HumaPen MEMOIR si l’une des pièces semble 

brisée ou endommagée. Contactez votre professionnel de la santé ou Lilly au 

1-888-545-5972 pour obtenir de l’aide.

www.lilly.ca

®

1

4

6

12

15

16

17

21

15

2

PA026SPCA00

PA026SPCA00

PA026SPCA00_covers _2a 1/2

Alcobendas

Site:

Affiliate  Barcode:

Previous Item Code 

(to be destroyed)

N/A

Item Code

PA026SPCA00

Start Date

20 MAY 2014

Technical

Information:

Size (mm):

512x162.5

Type:

Code:

Folded Size (mm)

Sick Code

N/A

CACAO No.

ALC14C074

No. of Pages: 

Translations of 

Variable Data

price:

other:

exp 

date:

mfg

date:

lot:

PPD Information Box

v4.01

ALRP Information Box

Layout name

ALC-PA0057-A

2a

Proof No. :

N/A

Feed Direction:

(For labels only)

Printing Colours

Technical Colours

Internal to MBS (no Lilly check required)
MBS Artwork Ref:

327116

Operator Name:

UE

Other Regulated 

Elements

Die Cut

N/A

N/A

N/A

N/A

N/A

185x162,5

Cover-Front

4/4 YELLOW

3/4 MAGENTA

2/4 CYAN

1/4 BLACK

N/A

N/A

N/A

Summary of Contents for HumaPen MEMOIR

Page 1: ...DISPLAY MESSAGES AND ERRORS AFFICHAGE DES MESSAGES ET DES ERREURS CARE STORAGE AND DISPOSAL ENTRETIEN CONSERVATION ET LIMINATION Fold out to see PEN PARTS diagram D pliez pour voir le diagramme des PI...

Page 2: ...ight 2013 Eli Lilly and Company All rights reserved Document revision date 12 December 2013 Garantie limit e du stylo HumaPen MEMOIR Eli Lilly and Company Lilly garantit que dans des conditions normal...

Page 3: ...us n amorcez pas le stylo jusqu ce que l insuline sorte vous pourriez recevoir trop ou pas assez d insuline Pour de plus amples renseignements voir l tape 8 Il est recommand d utiliser le stylo HumaPe...

Page 4: ...ignote Le stylo reviendra automatiquement au MODE PR T apr s 30 secondes d inactivit Press and release to increase by one Press and hold to scroll Appuyez et rel chez pour augmenter d un chiffre Appuy...

Page 5: ...el chez le de fa on r p t e jusqu ce que la bonne ann e apparaisse 1 Press ON button again The month will be flashing 2 Press and release end of dose knob until correct month is shown 1 Appuyez sur le...

Page 6: ...ssez l tape 5 Unscrew cartridge holder and remove from pen body D vissez le porte cartouche et enlevez le du corps du stylo Check the new cartridge to make sure it is not cracked or broken Insert smal...

Page 7: ...re the cartridge holder is completely and securely screwed onto the pen body before each injection If the cartridge holder is not correctly attached you may get too much or too little insulin Use the...

Page 8: ...he de 3 mL d insuline Humalog ou Humulin La couleur du stylo n est pas con ue pour indiquer le type d insuline Lisez et suivez les instructions qui accompagnent les cartouches de 3 mL des insulines Hu...

Page 9: ...ez le capuchon externe de l aiguille et gardez le Assurez vous que l aiguille est viss e fond sur le porte cartouche et que le porte cartouche est bien fix au corps du stylo Utilisez une nouvelle aigu...

Page 10: ...r s 30 secondes d inactivit afin d conomiser les piles You should see the above display for 2 seconds If any part of the pen display is missing do NOT use pen Vous devriez voir l affichage ci dessus p...

Page 11: ...rofessional or Lilly at 1 888 545 5972 QUESTIONS COURANTES Que dois je faire si le stylo ne se met pas en marche Assurez vous que vous avez bien appuy sur le bouton d allumage comme illustr dans le di...

Page 12: ...e holder gently with your finger so that any tiny air bubbles can collect near the top Slowly push straight on the dose knob as shown until dose knob stops When the dose knob stops continue to hold it...

Page 13: ...age Tenez le stylo avec l aiguille vers le haut loign e de votre visage Tapotez doucement le porte cartouche avec le doigt pour que les bulles d air remontent la surface R p tez l tape d amor age Il...

Page 14: ...shown Commencez par placer votre pouce directement sur le bouton de dose comme illustr Slowly push straight on dose knob until dose knob stops When the dose knob stops continue to hold it in and coun...

Page 15: ...artouche d insuline comme indiqu la section Changement de la cartouche d insuline et effectuez les tapes 3 13 en injectant seulement la quantit d insuline que vous n avez pas re ue Que dois je faire s...

Page 16: ...tically turn off after 30 seconds of inactivity Placez le capuchon sur le stylo Le stylo s teindra automatiquement apr s 30 secondes d inactivit SETTING AND INJECTING YOUR INSULIN DOSE S LECTION ET IN...

Page 17: ...errez un nombre dans la fen tre d affichage Prenez cette valeur en note Ce nombre correspond la quantit d insuline que vous N AVEZ PAS re ue Dial dose knob down to 0 This will save the first injection...

Page 18: ...dose knob again to go to READY MODE Note If dose knob is not pressed pen will return to READY MODE after 15 seconds Your HumaPen MEMOIR is tested at the factory and may contain several stored doses w...

Page 19: ...ays showing 5 units when dialing up or down do NOT use the pen Contact your healthcare professional or Lilly at 1 888 545 5972 Si 5 unit s apparaissent toujours sur l affichage lorsque vous tournez le...

Page 20: ...es ou si une partie appara t pendant la p riode de 1 seconde o l affichage est vierge N UTILISEZ PAS le stylo Contactez votre professionnel de la sant ou Lilly au 1 888 545 5972 No action needed Il n...

Page 21: ...ll return to READY MODE after 15 seconds of inactivity Il n y a rien faire L affichage reviendra en MODE PR T apr s 15 secondes d inactivit Press dose knob to go to READY MODE Display will return to R...

Page 22: ...ss ON button to go to next setting Appuyez sur le bouton de dose et rel chez le pour passer de l horloge de 12 heures a m p m l horloge de 24 heures Appuyez sur le bouton d allumage pour passer au pro...

Reviews:

Related manuals for HumaPen MEMOIR