background image

 

 

  

                                                                             

Suzhou  Lily  Tech.  Co.,  Ltd. 

                                                                                                                                                                                                             

www.suzhoulily.com.cn/en                                                                                                            Page  1, Total  2  Pages

 

ZL-6200A Temperature Controller 

Instruction Manual   A1.0 

 

Introduction 

ZL-6200A is for cooling, heating or warning control. Front panel water proof level IP65, control resolution 0.1

, keypad password 

protection. It is suitable to control or audit cold storage, aquarium, water heater, and so on. 
 

Main Function 

Cooling, heating or auditing 
Over temperature warning 
Sensor failure warning 

Temperature control 
Temp.  output  energized/de-energized  periodically  when 
sensor fails 

 
Specification 

Power supply: 185

 ~ 

245Vac, 50/60Hz 

Sensor: NTC, 1.5 meters long 
Display range: -50

 ~ 

120

 

Setting range: -50

 ~ 

120

 

Resolution: 0.1

 

Absolute accuracy: 1% at 25

 

Accuracy after calibration: 0.1

 

Temp. output, R1: 7A, 250Vac (

pure resistance load

Warning: Buzzing   

(When in warning mode, temp. output as warning output) 

Working: -10

 ~ 

45

, 5

 ~ 

90%RH without dew   

Dimension: W78 x H34.5 x D71 (mm) 
Installation drilling: W71 x H29 (mm) 
Case materials: PC + ABS fire proof 
Protection level: IP65 (Front side only) 
 

Keypad and Display 

Display 

Function 

On 

Blinking 

 

Heating mode 

Heating mode 

Setting set-point 

 

Cooling mode 

Cooling mode 

Setting set-point

 

AUX 

Warning mode 

Warning mode 

Setting set-point

 

 

Temp. output, R1 

R1 energized 

Delay protecting 

 

Warning 

---- 

Warning 

E1 

Warning

 

---- 

Sensor open 

E2 

Warning

 

---- 

Sensor short 

HH 

Warning

 

---- 

Over high temperature limit 

LL 

Warning

 

---- 

Bellow low temperature limit 

 
Operation 

On/off: 

Keep

S

depressed for 3 seconds to switch on/off. 

Check settings: 

Press

  to check the set-point; Press

  to check the hysteresis. 

Set Set-Point

 

Keep

S

depressed for 3 seconds to enter into the set status. The current set-point value displays. 

Press

or

  to set the value

 

(keeping depressed can fast set).   

Keep

S

depressed for 3 seconds to exit, and save the settings.   

The status will exit, and the setting will be saved, if no key operation within 30 seconds. 

Set System Parameters 

Keep

P

depressed for 3 seconds: If the password is not “0000”, digits show “---0”, else enter into parameter setting status.   

Press

to select the digit of the password, press

to set the value of the digit. 

Press

S

  to confirm: 

If the password is correct, enter into the parameter setting status, else exit. 

Set in parameter setting status: 

Press

or

to select the parameter code (see parameter code table below). 

Press

S

  to display the value of the code. 

Reviews: