BLD5/10 User Manual
BLDC50/100
User Manual
Assigning Addresses
Before the entire system is wired, each drive will need to connect individually to the host computer
so that it can be assigned a unique address.
Once the drive has been connected to the PC as described above, launch the BLD Configurator
software. Apply power to the drive. If a drive has already been configured, click the Upload button
so that the BLD Configurator settings match those of the drive. Click on the Motion button and se
-
lect the SCL operating mode. The numerals 0..9 or the special characters : ; < = > ? may be used
as addresses. Make sure each drive on the network has a unique address. Once the address has
been assigned, click Download to save the settings to the drive.
Address
SCL Character
Address
SCL Character
0
0
8
8
1
1
9
9
2
2
A
:
3
3
B
;
4
4
C
<
5
5
D
=
6
6
E
>
7
7
F
?
Lin Engineering
BLDC 50/100 Driver Manual
Page 10
Version 1.0
01/29/2020