IT-GB-FR
mod. 940-940/SA
55/112
CONTROL PANEL PUSH BUTTONS FUNCTIONS
Button 1 (P1)
-
Pushed for one time you enter into the heating plant water temperature
modification modality (use P1 and P2 to modify the value, P4 to exit).
-
Keeping it pushed, it indicates on the display the plant water temp. ,the
pressure of the boiler and the loading time of fuel.
-
Inside of a menu it modifies the value on video.
Button 2 (P2)
-
Pushed for one time you enter into the room temperature modification
modality (use P1 and P2 to modify the value, P4 to exit).
-
Keeping it pushed, it indicates on the display the temperature of the
outgoing fumes and the number revolutions/min. of the fumes expeller motor
-
Inside of a menu it modifies the value on video.
Button 3 (P3)
-
Pushed for one time you enter into the Menù of programming (use P5 and
P6 to run in the different menu, P3 to enter into the menù, P4 to exit).
-
Inside of a menu it confirms the value displayed on the video and proceeds
to the next one.
Button 4 (P4)
-
If pusched for few seconds it switches on/off the appliance.
-
If pushed inside of a menu you go back to the previous position or you exit
from the menu.
Button 5 (P5)
-
Pushed just one time, it enters in the function of the change of the Power
(use P6 and P5 to modify the value, P3 or P4 to exit).
-
Inside of a menu it allows to run forward the different menu and submenu.
Button 6 (P6)
-
Pushed for one time you enter into the domestic water temperature
modification modality (use P1 and P2 to modify the value, P4 to exit).
Setting
utilized only by appliances with domestic H
2
O service
-
Inside of a menu it allows to run back the different menu and submenu.
Summary of Contents for 0000
Page 15: ...IT GB FR mod 940 940 SA 15 112 Curve caratteristiche Circolatore ...
Page 34: ...IT GB FR mod 940 940 SA 34 112 ...
Page 35: ...IT GB FR mod 940 940 SA 35 112 ...
Page 36: ...IT GB FR mod 940 940 SA 36 112 ...
Page 37: ...IT GB FR mod 940 940 SA 37 112 ...
Page 52: ...IT GB FR mod 940 940 SA 52 112 Characteristic curves Circulator ...
Page 71: ...IT GB FR mod 940 940 SA 71 112 ...
Page 72: ...IT GB FR mod 940 940 SA 72 112 ...
Page 73: ...IT GB FR mod 940 940 SA 73 112 ...
Page 74: ...IT GB FR mod 940 940 SA 74 112 ...
Page 88: ...IT GB FR mod 940 940 SA 88 112 Courbes caractéristique circulatoire ...
Page 107: ...IT GB FR mod 940 940 SA 107 112 ...
Page 108: ...IT GB FR mod 940 940 SA 108 112 ...
Page 109: ...IT GB FR mod 940 940 SA 109 112 ...
Page 110: ...IT GB FR mod 940 940 SA 110 112 ...