IT-GB-FR
mod. 940-940/SA
62/112
MENU 08 (pellet correct)
Sometimes, changing type of pellet, there are so many types of wood pellet on the market, the
combustion of the appliance can be affected. A clear signal of an inefficient combustion is
given by the quantity of pellets into the burner basket during the normal working phase: too
much or too scarce. It is possible to make some small regulations on the combustion of the
appliance. Under the assumption that during the working phase the burner basket should be
full of pellet from ¼ to half of its capacity, whenever necessary, you can make some
adjustments following the below procedures:
a-
Observe the appliance and verify if the pellet is piling up till to the complete filling
of the basket or if the basket is emptying itself almost till to the extinction of the
fire.
b-
Push on button P3 to enter into the Menu.
c-
Run on the Menu utilizing the buttons P5 and P6 until you arrive to MENU 08
d-
Push again on button P3 to accede to MENU 08.
e-
An Access Key is requested, utilizing the button P1 or P2 run on the number in the
upper part of the screen until you arrive to number
33
.
f-
Push again on button P3 to confirm the Access Key and to enter into the modality of
combustion modification.
g-
Use buttons P1 and P2 to modify the number shown on the display on the upper
part, as indicated in the below table; to increase the quantity of pellet you must
increase the value, to decrease the quantity of pellet, decrease the value.
ATTENTION! We recommend to modify the value increasing/decreasing by only
one number per time. Verify the working of the appliance for one or two days, after
having cleaned the burner basket, only after this period of verification eventually
make a new regulation.
h-
Terminate the regulation of the carburetion pressing shortly on button P4.
increase pellets
decrease pellets
9
8
7
6
5
4
3
2
1
0
-1
-2
-3
-4
-5
-6
-7
-8
-9
MENU 9 (settings technic)
RESERVED TO TECHNICIANS.
DETAILS OF MENU
ATTENTION to the setting of the Time and the Date as they will affect the programmations
of the automatic switch ON/OFF
Menu 01 SET CLOCK - (setting up the clock inside the appliance).
Control panell Display
Description
Example
DAY
day of week
TUESDAY
CLOCK HOURS
hour of current time
15
(
15
:38)
CLOCK MINUTES
minutes of current time
38
(15:
38
)
CLOCK DAY
day of current date
11
(
11
/05/2010)
CLOCK MONTH
month of current date
05
(11/
05
/2010)
CLOCK YEAR
year of current date
10
(11/05/
20
10
)
Pay attention to the value of parameters during setting up, because a wrong setting up will
cause anomalies in the automatic switch ON/OFF programs.
Summary of Contents for 0000
Page 15: ...IT GB FR mod 940 940 SA 15 112 Curve caratteristiche Circolatore ...
Page 34: ...IT GB FR mod 940 940 SA 34 112 ...
Page 35: ...IT GB FR mod 940 940 SA 35 112 ...
Page 36: ...IT GB FR mod 940 940 SA 36 112 ...
Page 37: ...IT GB FR mod 940 940 SA 37 112 ...
Page 52: ...IT GB FR mod 940 940 SA 52 112 Characteristic curves Circulator ...
Page 71: ...IT GB FR mod 940 940 SA 71 112 ...
Page 72: ...IT GB FR mod 940 940 SA 72 112 ...
Page 73: ...IT GB FR mod 940 940 SA 73 112 ...
Page 74: ...IT GB FR mod 940 940 SA 74 112 ...
Page 88: ...IT GB FR mod 940 940 SA 88 112 Courbes caractéristique circulatoire ...
Page 107: ...IT GB FR mod 940 940 SA 107 112 ...
Page 108: ...IT GB FR mod 940 940 SA 108 112 ...
Page 109: ...IT GB FR mod 940 940 SA 109 112 ...
Page 110: ...IT GB FR mod 940 940 SA 110 112 ...