IT-GB-FR
mod. 940-940/SA
65/112
Activate(on) / Deactivate(off) to make operative or to exclude the programmings of the week
M-2-4-02
START 1 WEEK-END
Insert 1 starting hour
07:00
00:00-off
M-2-4-03
STOP 1 WEEK-END
Insert 1 extinction hour
12:00
00:00-off
M-2-4-04
START 2 WEEK-END
Insert 2 starting hour
14:00
00:00-off
M-2-4-05
STOP 2 WEEK-END
Insert 2 extinction hour
off
00:00-off
The program hours will be repeated every day of the week in the same way. For a correct
execution of the programs, set very carefully the data of Menu 01.
Selecting oFF instead of the starting or extinction hour, the appliance exclude the automatic
starting or extinction
Menu 03 SELECT LANGUAGE - (setting up the language of the control panel).
Display
Description
Example
SELECT
LANGUAGE
Set up the language of the control panel
ENGLISH
Available languages : ITALIAN, ENGLISH, DEUTSCH, FRANCAIS
Menu 04 STATUS STAND-BY - (Set up way of appliance extinction according to the room
and boiler temperatures).
Display
Description
Example
STATUS STAND-BY
Activate(on) / Deactivate(off) the stop modality if the set room or
boiler temperatures have been exceeded .
oFF
Available selections : on, oFF
ON, If the appliance is exceeding 2°C the set value of room or boiler temperature, it starts the
extinction cycle.
OFF, If the appliance is exceeding the set value of room or boiler temperature, it will continue to work
at min. power, without extinctinguishing.
Menu 05 STATUS BUZZER - (Setting up of buzzer sound).
Display
Description
Example
STATUS BUZZER
Select the buzzer modality you wish
ONLY ALARM
Available selections: OFF, ONLY ALARMS, ALWAYS ON
OFF – Always off
ONLY ALARMS – Sounds only if an alarm has occurred.
ON ALWAYS, sound in case of alarm and at any tuch of the buttons of the control panel.
Menu 06 LOAD INITIAL - (Continuos fuel load setting).
Display
Description
Example
LOAD INITIAL
Activates the continuos load of fuel
this operation can only be effected when the appliance on the display is evidencing “OFF”. This menu is
utilized to fill the screw feeder when the appliance is new or in case of emptying of the pellet container.
Menu 07 STATUS STOVE - (Displays the status of the appliance).
Display
Description
Example
STATUS STOVE
Shows informations about the working of the appliance
Displayed values:
Fume temperature, fume expeller motor rev/min, appliance status, room temperature, boiler pressure,
time of fuel loading, and a screening of informations for TECHNICIANS.
Menu 08 PELLET CORRECT - (Correction of appliance combustion).
Display
Description
Example
PELLET CORRECT
Combustion modification
ACCESS KEY
Insert access key to accede to the combustion modification
33
PELLET CORRCT
Correction of the load of fuel
-02
Summary of Contents for 0000
Page 15: ...IT GB FR mod 940 940 SA 15 112 Curve caratteristiche Circolatore ...
Page 34: ...IT GB FR mod 940 940 SA 34 112 ...
Page 35: ...IT GB FR mod 940 940 SA 35 112 ...
Page 36: ...IT GB FR mod 940 940 SA 36 112 ...
Page 37: ...IT GB FR mod 940 940 SA 37 112 ...
Page 52: ...IT GB FR mod 940 940 SA 52 112 Characteristic curves Circulator ...
Page 71: ...IT GB FR mod 940 940 SA 71 112 ...
Page 72: ...IT GB FR mod 940 940 SA 72 112 ...
Page 73: ...IT GB FR mod 940 940 SA 73 112 ...
Page 74: ...IT GB FR mod 940 940 SA 74 112 ...
Page 88: ...IT GB FR mod 940 940 SA 88 112 Courbes caractéristique circulatoire ...
Page 107: ...IT GB FR mod 940 940 SA 107 112 ...
Page 108: ...IT GB FR mod 940 940 SA 108 112 ...
Page 109: ...IT GB FR mod 940 940 SA 109 112 ...
Page 110: ...IT GB FR mod 940 940 SA 110 112 ...