Wrong pressure of thermal
plant.
Verify thermal plant pressure.
(min. 0,5bar max. 2bar).
Press
Water
Noticed
wrong boiler
pressure.
Too high pressure
Electrical connections
interrupted.
Reduce the pressure of the plant by
draining water.
Verify the electrical connections of
pressure switch.
Pressure switch control
breakdown.
Verify/replace pressure switch
control.
Feeler
Water
Boiler
temperature
feeler
signaling
error.
Verify/replace temperature feeler.
Feeler
exhaust
Exhaust feeler
signaling error
Verify/replace exhaust feeler.
Wrong appliance
carburation.
Verification of appliance by a
technical service center.
Proceed with “Pellet Correct”.
Hot
exhaust
Fume
temperature
too high
Change fuel.
Verification of appliance by a
technical service center.
Utilize better quality of pellet .
Proceed with “Pellet Correct”.
Fume feeler
Verify fume feeler position.
Verify/replace fume feeler.
Wrong appliance
carburation
Verification of appliance by a
technical service center.
Proceed with “Pellet Correct”.
Hot
Water
Boiler water
temperature
too high
Breakdown/block
circulation plant pump.
Air inside the boiler.
Verify circulation pump working
Eliminate air from the thermal plant
Fume feeler
.
Verify boiler feeler position.
Verify/replace boiler feeler.
Black-Out
A black-out
has happened
during the
regular
working.
Empty and clean the burner basket
and then proceed with the lighting
phase.
EXAMPLES OF APPLIANCE/PLANT CONNECTION
The following connection diagrams are only indications of some connection
possibilities and should not be considered as satisfaction in matter of installations.
Summary of Contents for 0000
Page 15: ...IT GB FR mod 940 940 SA 15 112 Curve caratteristiche Circolatore ...
Page 34: ...IT GB FR mod 940 940 SA 34 112 ...
Page 35: ...IT GB FR mod 940 940 SA 35 112 ...
Page 36: ...IT GB FR mod 940 940 SA 36 112 ...
Page 37: ...IT GB FR mod 940 940 SA 37 112 ...
Page 52: ...IT GB FR mod 940 940 SA 52 112 Characteristic curves Circulator ...
Page 71: ...IT GB FR mod 940 940 SA 71 112 ...
Page 72: ...IT GB FR mod 940 940 SA 72 112 ...
Page 73: ...IT GB FR mod 940 940 SA 73 112 ...
Page 74: ...IT GB FR mod 940 940 SA 74 112 ...
Page 88: ...IT GB FR mod 940 940 SA 88 112 Courbes caractéristique circulatoire ...
Page 107: ...IT GB FR mod 940 940 SA 107 112 ...
Page 108: ...IT GB FR mod 940 940 SA 108 112 ...
Page 109: ...IT GB FR mod 940 940 SA 109 112 ...
Page 110: ...IT GB FR mod 940 940 SA 110 112 ...