mod. 470-480L-490L-480N-490N GB
17/20
Windows fire door and/or
combustion chamber are
dirty of soot.
−
Low draft <10 Pa.
−
Wrong regulation.
−
Too much combustible
introduced.
−
Combustible with high
humidity level.
−
Not good quality
combustible.
−
Check that the exhaust fumes
tube is not obstructed.
−
Modify the flue : increase the
flue’s hight, end units not
correct, improve the isolation /
seal
−
Read the charter “ Regulations”.
−
Reduce the quantities.
−
Employ dried wood.
−
Read the chapter “ Combustible”.
Not regular draft
−
Flue / exhaust fumes
unsuitable or dirty.
−
Stove is dirty inside.
−
Require chimney sweep
intervention.
−
Clean the stove.
Too much dark fumes
from the exhaust
−
Stove light on with
green wood.
−
Stove dirty inside.
−
Light on the stove with dried
wood.
−
Call the assistance service.
Fumes escape from the
stove
−
The fire/ash door is open
while the fire is burning.
−
Draft insufficient.
−
Not correct regulation
during ignition operation
−
The stove should be
cleaned.
−
Close the doors.
−
Call the chimney – sweeper to
check the chimney flue.
−
Read the chapter “ Regulations”
and “ Combustible to employ”.
−
Clean all the connection tubes
and the chimney.
Every intervention has be done from qualify staff !
Lincar S.p.A is not responsible for damages to thing or people due to a wrong installation,
equipment tampering, improper use, bad maintenance or no observation of normative in
force. I f considerate appropriate, Lincar spa reserves the right to make modifications without
notice and in every moment.
Some particulars and accessories illustrated in this handbook are not mass produced item so its
extra costs are to check at contract release.
Note:_______________________________________________________________________