mod. 470-480L-490L-480N-490N GB
3/20
1
INS TALLATION
RES ERVED TO INS TALLER
1.1
Normative and prescriptions
•
Read carefully the contents of this handbook, it contains important information and
instructions for installation, use, maintenance and product safety.
•
The appliance must be installed inside an environment considered suitable for installation
and use by competent authorities. All laws, standards and regulations in force on the
installation site must be observed, especially regarding fire prevention.
•
Technological connection and appliance installation must be carried out by qualify staff
authorized to release a conformity certificate according with the normative in force and
current standards.
•
All the normative concerning civil town planning and/or industrial in force must be
respected inside the environment of installation of the appliance. In every case the safety
devices should be always employed.
•
The installation must be carried out and certified according to the normative in force
regarding installations, exhaust fumes connections, electricity, water, ventilation /
suction.
•
The manufacturer disclaims all responsibility caused by no correct installation,
using, tampering, maintenance or no respect of normative in f orce.
1.2
Pre liminary ope rations
•
Take away the packing.
•
Before installation, check the appliance integrity. In case of doubt, do not use the
appliance and call the dealer.
•
Packing materials is for recycle, getting it in the specify container.
1.3
Appliance positioning
•
The installation environment should have :
−
A suitable floor for stove weight and calorific radiation, otherwise preventive
measures should be adopted. (Ex. Plate for charge distribution ).
−
A suitable floor for stove calorific radiation to guarantee the building against any
fire risk.
−
The stove should be installed so that gas flue, chimney and cleaning could be easily
done.
−
A minimal distance from fla mmable materials ( Security Distances)
−
A suitable ventilation as normative in force.
FLOOR PROTECTION
•
The equipment has to be put on a refractory surface. In case of flammable floor
( carpet, parquet ..) it’s necessary to put a refractory base( stainless steel, ceramic etc )
with the following dimensions :
−
Hold up in front
≥
500 mm;
−
Hold up lateral
≥
350 mm;
−
Hold up back
≥
100 mm.