IS792 ECN 4879
Page 11 of 37
TECHNICAL DATA
Environmental Operating Conditions
-Nominal environmental operating condition:
Climatic class 5
( 40°C, HR%=40%);
- Ambient temperature operating range:
10°C~40°C
;
- Humidity:
60% maximum, non-condensing
;
-Electrical supply:
110~127V/60Hz; 220~230V/50Hz; 220V/60Hz;
-Altitude:
2000 meters MSL
(Mean Sea Level);
- Usage:
This product is intended for use indoors only
.
Below is the table showing the technical data of the various models of blast chillers and
freezers.
Soft blast chilling cycle: Manual with Air set at 0°C
Hard blast chilling cycle:
o
First step air set at 0°C
o
Second step air set at -20°C
Shock freezing cycle: Manual with Air set at -40°C
Model
Blast chilling
power
consumption
[kW]
Shock
freezing
power
consumption
[kW]
Blast
chilling
yield
[Kg]
Shock
freezing
yield
[Kg]
Gas
charge
R452A
[Kg]
Blast
chilling
cycle time
(+90°C ÷ +3°C)
Shock
freezing
cycle time
(+90°C ÷ -18°C)
BGBF-5P
1,1
0,6
14
8
1,0
90
270
BGBF-10
2,7
1,3
30
20
2,0
90
270
Note
: All relevant data referring to these products can be found on the data label visible
either on the rear part of the cabinet or inside the cooled compartment . Here is an
example of the label:
How to read the Serial Number:
YY
POP
XXXXXX
Last two numbers of the production
Progressive serial number of 6 digits