IS792 ECN 4879
Page 22 of 37
•press
B12
: display
DY1
will show the label of the first program
•press
B4
or
B6
to select a program
•press
B1
To display the label of the current program:
•press
B12
4.10.8 Additional functions accessible during operational cycles
To display the cabinet temperature during a set-temperature chilling step or during a set-
temperature freezing step:
•press the key related to the current cycle: display
DY1
displays the cabinet
temperature for 5 s.
To display the temperature detected by the needle probe during a timed chilling step,
timed freezing step or during storage:
•press
B2
: display
DY1
shows the temperature measured by the needle
probe for 5s.
To display the time elapsed since starting a chilling or freezing step:
•press
B4
: display
DY2
shows the elapsed time for 5 s.
If the key is pressed during the storage phase, display
DY2
will show the effective duration
of the chilling or freezing cycle.
4.11 SETTINGS
4.11.1 Setting the date and time
To access the procedure:
•ensure the device is in "off" mode and no procedures are running
To adjust the date and time:
•press
B3
for 5 s: display
DY1
will show "YY" and display
DY2
will show the
last two digits corresponding to the year
•press
B4
or
B6
to change the year
•press
B3
: display
DY1
will show "NN" and display
DY2
will show the digits
corresponding to the month (the month is displayed in 12 month format)
•press
B4
or
B6
to change the month