CHECK LIST OF ENCLOSURES
Warranty card
Instructions manual
Baskets
Lid knob
Drain tube
Element lifting hook
Feet (J models)
Stability Bracket (J6, J9)
INSTALLATION AND COMMISSIONING
This appliance must be earthed.
An equipotential bonding terminal is provided to allow cross bonding with other
equipment.
If replacing the plug connect the terminals as follows:
Green and Yellow wire Earth E
Blue wire Neutral N
Brown wire Live L
Means of isolation with at least 3mm contact separation in all poles must be
incorporated into the fixed wiring of this appliance.
The fixed wiring insulation must be protected by insulated sleeving having a
temperature rating of at least 60 Deg C.
Supply cords shall be oil resistant, sheathed flexible cable not lighter than ordinary
polychloroprene or equivalent elastomer sheathed cord (code 60245 IEC 57)
Install this appliance on a level surface ensuring all vents are unobstructed. Any
partitions, walls or furniture must be of non-combustible material. Minimum
distances A 100mm B 1000mm
– see Fig 1.
Operate this appliance beneath an extraction canopy.
Models up to 3kW are fitted with a plug and lead. Models over 3kW must be
installed by a qualified electrician