IS726   ECN 4530 

Page 7 of 10 

 

 

 

Insert the new filter into the recess and lock in place by twisting to the right. 

 

Press the 

“Filter life icon” and follow the on-screen instructions to reset the filter life. 

 

Drain off approximately 5 litres of water to remove any loose carbon particles from the 
filter.  
 
The boiler will not fill if the filter is removed as the filter head incorporates a shut-off 
valve. 
 

F10-Chiller condenser over heat: This could be due to condenser fan not working, 
condenser air outlet blocked or condenser blocked. 
 
F11-Chiller- clean condenser: This is a regular periodic warning to ensure the condenser 
fins are not blocked that should be kept clean to ensure optimum operation of cooler water 
cooling system.   

 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

CLEANING

 

 
 
 

Do not use a water jet or steam cleaner, and do not immerse this appliance. 

 

Clean all panels with warm water and mild detergent and do not use abrasive    

materials.  Dry with a soft cloth. 
 
Slide out and empty the drip tray regularly, and wipe the dispensing tap spouts daily 
to remove limescale deposits. 

 

SPARES LIST

 

 Part number  Description 

PR111 

Control/Display board 

PR101 

Auxiliary power board  

PR100 

Power board 

TH88 

Tank over heat cut out 

TH123 

Steam/over flow over heat cut out 

TH124 

Hot tank thermistor 

TH126 

Cold block thermistor 

WL13 

Level sensor cable 

CA179 

Interconnect data cable 

CA207 

Condenser signal cable 

EBCM01 

Chiller module 

Summary of Contents for EB3FX/HC/PB

Page 1: ...ler and chiller EB3FX HC PB Please make a note of your product details for future use Date Purchased _________________________ Model Number __________________________ Serial Number __________________________ Dealer _________________________________ _______________________________________ ...

Page 2: ...Service Information and Guarantee 9 IMPORTANT INFORMATION Read these instructions carefully before using this product paying particular attention to all sections that carry warning symbols caution symbols and notices Ensure that these are understood at all times WARNING This symbol is used whenever there is a risk of personal injury CAUTION This symbol is used whenever there is a risk of damaging ...

Page 3: ...ce of heat which may result in operating condition exceeding its design limits Ambient temperature range minimum 160C maximum 320C Maximum relative humidity 70 Switching on If the unit has been laying on it s side then allow at least 3 hours in upright position before switching on If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified person ...

Page 4: ...plug connect the terminals as follows Green and Yellow wire Earth E Blue wire Neutral N Brown wire Live L Install this appliance on a level surface ensuring all vents are unobstructed Only install this unit in locations where it can be overseen by trained personnel Inlet water pressure should be between 2 and 6 bar 0 2MPa to 0 6MPa If water pressure exceeds 6bar fit a suitable pressure reduction v...

Page 5: ... If solid particles are known to be in the supply add an extra inline filter or strainer OPERATING INSTRUCTIONS General arrangement 1 2 3 4 5 6 7 8 9 10 12 11 13 14 Only qualified or trained personnel should use this appliance 1 Lid 9 Drain pipe thermal trip reset 2 Touchscreen display 10 Pressure reducing valve 3 Dispense button cold 11 Water inlet point 4 Dispense spout cold 12 Side condenser ai...

Page 6: ...ter PIN code is available from Lincat Service should you forget the user set PIN Filter Replacement The filter display shows the estimated life remaining in the filter cartridge A reminder message is displayed when the filter needs changing To replace the filter Twist the base of the filter E 90 degrees to the left and lower the cartridge out of the appliance It will contain a small amount of wate...

Page 7: ...warning to ensure the condenser fins are not blocked that should be kept clean to ensure optimum operation of cooler water cooling system CLEANING Do not use a water jet or steam cleaner and do not immerse this appliance Clean all panels with warm water and mild detergent and do not use abrasive materials Dry with a soft cloth Slide out and empty the drip tray regularly and wipe the dispensing tap...

Page 8: ...REPLACEMENT All maintenance and component replacement on this appliance should be carried out by one of our recommended service engineers Please refer to the Service Help Desk number on the final page of this manual For spare parts for your water boiler chiller please contact the Lincat Spares department on 01522 875510 Refer to the serial plate for the model and serial number of your water boiler...

Page 9: ... to Friday 08 30 to 17 00 GUARANTEE This unit carries a comprehensive UK mainland 2 year warranty This requires you maintain and care for your product and follow maintenance instructions If you fail to maintain your unit or damage components Lincat may charge you for a warranty repair The guarantee is in addition to and does not diminish your statutory or legal rights The guarantee does not cover ...

Page 10: ...IS726 ECN 4530 Page 10 of 10 This page intentionally blank ...

Reviews: