background image

IS 599   ECN 3856 

Page 7 of 9 

 

 

SERVICING, MAINTENANCE AND COMPONENT 
REPLACEMENT 

 
 

Your Lincat product has a manufacturer’s warranty. This requires you to maintain 
and care for your product and follow maintenance instructions. If you fail to maintain 
your unit or damage components Lincat may charge you for a warranty repair. 
Please check the website for terms and conditions. 
 
All servicing, maintenance and component replacement on this appliance should be 
carried out by one of our recommended service engineers. 

 

 

 

Component replacement 

 

The following components are all accessed by turning the appliance either on to the 
side or top and then removing the control panel and base panel section. 

 

 

 

Neon 

 

 

 

Remove the cables from the neon and unscrew the retaining collar. 

 
 

Withdraw the neon. 
 
Fit the new neon and reverse the procedure to reassemble. 
 

Element 

 
Disconnect the cables from the element terminals and withdraw the control 
thermostat and safety thermostat bulbs. 
 
Undo the nuts holding the element and support ring to the tank. 
 
Remove the element and seal from the inside of the tank. 
 
Ensure the mating face of the tank is clean.  Fit new element and seal assembly. 
 
Reverse the procedure to reassemble. 
 

Control thermostat 

 
Remove the control knob 

– do not loose the clip. 

 
Slide the thermostat bulb from the element mounting. 
 
Remove cables from the thermostat, unscrew thermostat from the facia panel. 
 
Fit new thermostat and reverse procedure to reassemble. 
 

 
 
 

Summary of Contents for OE8601

Page 1: ...ric Wet Well Bain Marie OE8601 Please make a note of your product details for future use Date Purchased _________________________ Model Number __________________________ Serial Number ________________...

Page 2: ...ation and Guarantee 9 IMPORTANT INFORMATION Read these instructions carefully before using this product paying particular attention to all sections that carry warning symbols caution symbols and notic...

Page 3: ...that the plug socket is accessible at all times Strip plastic coating and clean the appliance before use During operation parts may become hot avoid accidental contact Disconnect this appliance before...

Page 4: ...le cable not lighter than ordinary polychloroprene or equivalent elastomer sheathed cord code 60245 IEC 57 Install this appliance on a level surface ensuring all vents are unobstructed Any partitions...

Page 5: ...operation of the element as it maintains temperature Check and maintain the water level in the tank do not allow appliance to boil dry Shutdown To shutdown rotate the control knob to the Off position...

Page 6: ...remove we recommend using approved de scaler MS19 available from Lincat To de scale the appliance first disconnect from the electricity supply Remove all gastronorm pots from the tank and fill the ta...

Page 7: ...e or top and then removing the control panel and base panel section Neon Remove the cables from the neon and unscrew the retaining collar Withdraw the neon Fit the new neon and reverse the procedure t...

Page 8: ...vice Help Desk number on the final page of this manual Part Number Description EL212 Element KN500 Control knob LE38 Leg NE46 Green neon NE47 Amber neon PL202 Plug and lead TH66 Control thermostat TH6...

Page 9: ...t diminish your statutory or legal rights The guarantee does not cover Accidental damage misuse or use not in accordance with the manufacturer s instructions Consumable items such as filters glass bul...

Reviews: