IS361 ECN3258
3
Fig 3
Lighting the Appliance
Please ensure that the gas isolation valve for the appliance is turned to the open position before
attempting to light this unit.
1.
Ensure that the thermostat control knob
(see fig 1.)
is in the OFF position.
2.
Press the pilot knob in and turn anticlockwise to the Pilot position
(see fig 2.)
3.
Keeping the pilot control knob depressed, press the piezo ignition button
(see fig 3.)
4.
Hold the pilot control knob in for 20 seconds to establish the pilot flame.
5.
If the pilot flame fails to ignite, return the pilot control knob to the off position and repeat the process
allowing a short period of time for the control to reset.
6.
When the pilot is lit, release the pilot control knob and turn fully anti-
clockwise to the ‘Main Burner’ position
(see fig 2).
7.
To operate the main burner, turn the thermostat control knob
(see fig 1.)
to the required
temperature setting.
Standby
Once the pilot is lit the appliance may be left on standby by leaving the pilot control knob in the pilot ign
ition position. When in this position the appliance cannot be operated from the thermostat control knob.
To re ignite the main burners follow steps 6 and 7 above.
Note: Should the safety cut out thermostat operate during normal use the unit will shut down.
To re-light the unit allow the oil to cooled to a temperature below 200
o
C. Reset the safety
thermostat by depressing the red reset button. (see fig 3). To reset the unit, open the door(s)
- the reset button(s) are located at the base of the left hand frame pillar. The button is in the
centre of the protruding threaded tube.