background image

IS 592   ECN 3855 

Page 11 of 13 

 

 

 
 

Pilot will not light 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Pilot will not remain lit 

 
 
 
 
 
 
 
 
 
 
 

FAULT FINDING

 

CHECK IGNITER FOR SPARKING 

CHECK GAS  

SUPPLY IS ON 

CONNECT TO 

CORRECT GAS TYPE 

YES 

YES 

NO 

CHECK IGNITER LEAD 

CONNECTIONS 

IS GAS TYPE CORRECT 

ADJUST AS 

NECESSARY 

CHECK PILOT INJECTOR FOR 

BLOCKAGE 

CLEAR BLOCKAGE / 

REPLACE INJECTOR 

NO 

CHECK OPERATING 

PRESSURE 

CHECK GAS FLOW TO 

PILOT 

PURGE SYSTEM 

CHECK MILLIVOLT OUTPUT OF 

THERMOCOUPLE 

REPLACE 

THERMOCOUPLE 

<4mV 

>4mV 

REPLACE THERMOSTAT 

Summary of Contents for Opus 800 OG8201

Page 1: ...1 OG8201 R OG8201 C OG8202 OG8202 R OG8202 C Please make a note of your product details for future use Date Purchased _________________________ Model Number __________________________ Serial Number __...

Page 2: ...rvice Information and Guarantee 14 IMPORTANT INFORMATION Read these instructions carefully before using this product paying particular attention to all sections that carry warning symbols caution symb...

Page 3: ...services before cleaning or servicing maintenance TECHNICAL DATA OG8201 OG8202 Dimensions Height mm 530 Width mm 600 900 900 900 Depth mm 800 Weight Kg 82 5 98 0 105 98 0 Plate weight Kg 45 53 0 60 5...

Page 4: ...bstances harmful to health in the room of installation There must be a minimum free area of 4 5cm2 per kW of total heat input Allow for a sufficient flow of fresh air for complete gas combustion Do no...

Page 5: ...per hour per kW of installed capacity If the appliance must be fitted near walls partitions kitchen furniture etc we recommend they are made from non inflammable material otherwise they should be cove...

Page 6: ...to the gas supply check for soundness and then purge the appliance by rotating all control knobs to the ignition position and depressing them Hold the knobs depressed to purge the supply pipe and inte...

Page 7: ...check the fat drawer to prevent overflow Shutdown To shut down the appliance rotate all control knobs to the Off position Shut off the gas at the supply CLEANING Do not use a water jet or steam cleane...

Page 8: ...be carried out by one of our recommended service engineers The griddle plate is very heavy and assistance will be required to raise and remove the plate from the appliance Care must be taken to avoid...

Page 9: ...the thermostat Remove the clamp from the manifold to free the thermostat Feed the capillary and bulb from the thermostat through the bulkhead Fit the new thermostat and make good all connections Perf...

Page 10: ...raw the thermocouple Fit the new thermocouple and re assemble in the reverse order This appliance cannot be converted by the user For conversion kit and instructions of how to convert contact Lincat d...

Page 11: ...IS ON CONNECT TO CORRECT GAS TYPE YES YES NO CHECK IGNITER LEAD CONNECTIONS IS GAS TYPE CORRECT ADJUST AS NECESSARY CHECK PILOT INJECTOR FOR BLOCKAGE CLEAR BLOCKAGE REPLACE INJECTOR NO CHECK OPERATIN...

Page 12: ...d KN510 Control knob FE40 Adjustable leg PI25 Pilot assembly SC01 Scraper TC03 Thermocouple TC05 Thermocouple lock nut TC06 Thermocouple sleeve TC24 Thermocouple capillary lock nut TH202 Thermostat WA...

Page 13: ...ot diminish your statutory or legal rights The guarantee does not cover Accidental damage misuse or use not in accordance with the manufacturer s instructions Consumable items such as filters glass bu...

Reviews: