IS 592 ECN 3855
Page 9 of 13
Place bulbs to one side, avoiding damage to the capillaries. Lift plate free from the
appliance.
When re-fitting the plate, ensure capillaries are routed away from the burners and
do not become trapped at any point.
Component Replacement
Control thermostat
Remove the control knobs, facia panel and raise griddle plate.
Remove the nut from the gas output pipe at thermostat.
Remove the nut from the pilot output at the thermostat.
Remove the thermocouple nut from the thermostat.
Remove the clamp from the manifold to free the thermostat.
Feed the capillary and bulb from the thermostat through the bulkhead.
Fit the new thermostat and make good all connections.
Perform a gas soundness test prior to continued operatio
Burner
Remove the griddle plate.
Remove the burner injector lock nut and the burner retaining screw located above
the burner injector.
Lift the burner free from the chassis, fit the new burner and re-assemble in the
reverse order.
Pilot Igniter electrode
Remove the griddle plate.
Remove the igniter lead at the igniter.
Remove the igniter retaining screw from the pilot assembly and replace the igniter.
Re-assemble in the reverse order.