IS 576 ECN 3872
Page 4 of 10
INSTALLATION AND COMMISSIONING
This appliance must be earthed.
An equipotential bonding terminal is provided to allow cross bonding with other
equipment.
If replacing the plug connect the terminals as follows:
Green and Yellow wire Earth E
Blue wire Neutral N
Brown wire Live L
Means of isolation with at least 3mm contact separation in all poles must be
incorporated into the fixed wiring of this appliance.
The fixed wiring insulation must be protected by insulated sleeving having a
temperature rating of 60 Deg C.
Supply cords shall be oil resistant, sheathed flexible cable not lighter than ordinary
polychloroprene or equivalent elastomer sheathed cord (code 60245 IEC 57)
Install this appliance on a level surface ensuring all vents are unobstructed.
Power Ratings
P10 (kW)
P8 (kW)
Bain Marie
2 x 1
1
Water Boiler
2 x 3
3
Hot Cupboard
2.5
2.5
Crisp ‘N’ Hold
1.820
1.820
Gantry Top Shelf
1.800
1.5
Gantry Mid Shelf
1.800
1.5
Gantry Top Shelf
0.6
0.3
Total Power
16.52 (71.83A)
11.92 (51.84A)
L1
6 (26.1A)
4 (17.4A)
L2
5.1 (22.17A)
4 (17.4A)
L3
5.42 ( 23.56A)
3.62 (15.74A)