background image

IS707 ECN 4277 

 

Pan detection function 

 
This prevents the coils being turned on without a pan being present, and also turns 
off the coil as soon as a pan is removed.  If the pan is of the wrong material for 
induction equipme

nt, the ‘no pan present’ symbol is displayed.  After use, switch off 

the hob via the control and do not rely on the pan detector. 
 
 
 

Residual heat display 

 
When the temperature of the hob top exceeds 60

o

C after removal of a pan, the ‘H’ 

symbol displays, indicating a hot surface.  (Refer also to the error codes section).  
Whilst the residual heat display is showing, leaving the appliance connected to the 
power supply allows the cooling fans to continue to operate.  When the ‘H’ symbol is 
extinguished, switch off the power supply. 
 

Error codes 

 

There are numerous error codes identifying issues within the induction system.  These 
are primarily of use when reporting a fault to 

Lincat’s Service Department; however 

some errors can be cleared by turning the control 

to the ‘Off’ position, unplugging the 

appliance and then switching back on again. 

 

A reduction in performance during cooking may be attributed to a blocked or    restricted 
air filter, a confined location with insufficient airflow or a failed cooling fan. 

 

Error codes are shown on the display 

This list shows the standard error codes. As standard general TC (thermocouple) 
errors are 

“Er xx“and cooking element specific errors E/x are displayed. 

 

Error code

 

Description

 

Possible cause of error

 

Remedy

 

Er  03  and 

continuous 

tone or 

 

 

continuous sensor activation; TC 

turn off after 10 sec 

Water or cookware on the 

glass over the touch 

control sensors 

Clean the control surface, 

remove objects on the 

sensors 

Er  20 

Flash memory 

– TC error 

µC-  defective 

Replace TC 

 

Er 22 

 

Button evaluation defective, UI 

shuts off after 3.5-7.5 sec 

 

Short or open circuit in the 

area of the button sensor 

 

Replace TC 

 

Er 31 

Incorrect configuration data or 

deviation between generator and 

TC 

New configuration of the 

induction generator 

required 

New configuration (Service 

menu) 

Er 36 

NTC value defective on TC; UI 

turns off 

Short or open circuit of 

NTC 

Replace TC 

 

Er 47 

 

Communication error between 

TC and induction 

No or erroneous LIN 

communication! (Slave 

does not answer to 

request of master) 

Connection cable not 

correctly plugged in or 

defective. 

U 400 

Continuous tone 

Power supply on inlet to high 

Incorrect connection of the 

cooktop 

Correct power supply 

connection 

E / 2 

Excess temperature of the 

induction element 

Overload of cooktop or 

empty boiled cookware 

Let system cool down. 

E / A 

Error on the power board 

Component failure 

Replace power board 

Summary of Contents for Phoenix PHER01-A002

Page 1: ... Range PHER01 A002 PHER01 SPH A001 Please make a note of your product details for future use Date Purchased _________________________ Model Number __________________________ Serial Number __________________________ Dealer _________________________________ _______________________________________ ...

Page 2: ...Guarantee 13 IMPORTANT INFORMATION Read these instructions carefully before using this product paying particular attention to all sections that carry warning symbols caution symbols and notices Ensure that these are understood at all times WARNING This symbol is used whenever there is a risk of personal injury CAUTION This symbol is used whenever there is a risk of damaging your Lincat product NOT...

Page 3: ...e During operation parts may become hot avoid accidental contact Disconnect this appliance before servicing maintenance or cleaning If the ceramic glass surface is cracked immediately disconnect the appliance from the supply Do not stand on the unit Surfaces are not to be used for storage The ceramic glass is very strong but do not slam pans down onto it and be careful not to scrape pans along the...

Page 4: ...the bottom connector Do not crosslink the lives or neutrals CHECK LIST OF ENCLOSURES Warranty card Instruction manual INSTALLATION AND COMMISSIONING This appliance must be earthed An equipotential bonding terminal is provided to allow cross bonding with other equipment If replacing the plug connect the terminals as follows Green and Yellow wire Earth E Blue wire Neutral N Brown wire Live L1 Black ...

Page 5: ...evel should be fitted A short time delay AC DC sensitive RCD is recommended Install this appliance on a level surface ensuring all vents are unobstructed Any adjacent partitions walls or furniture must be of non combustible material To avoid heat damage to the induction modules do not place this appliance next to hot appliances such as ranges and griddles without following the minimum distances st...

Page 6: ...nduction cooking produces heat directly in the base of the pan The system comprises a ceramic glass hob with an induction coil beneath it The coil generates an alternating magnetic field When a pan with a magnetic base is placed on the cooking zone eddy currents are produced in the base of the pan leading to the production of heat The pan heats extremely quickly The quality of the cookware is esse...

Page 7: ...he rotary control knob There are a number on features available to you to enhance your appliances productivity The following symbols are displayed through the glass Melt Keep warm and Simmer functions Power level setting 1 9 Power boost function Automatic heat up control Control lock function Pan detection no pan present Residual heat display Error codes generator Error rotary control lightning sy...

Page 8: ...reverting to level 9 It may be boosted again providing the system internal temperatures are satisfactory Automatic heat up control AHC When activated the AHC will give maximum power level 9 to a coil for a pre set time before reducing to a lower power level set by the control To activate the control is turned anticlockwise from the Off position briefly whilst the A symbol illuminates the control i...

Page 9: ...flow or a failed cooling fan Error codes are shown on the display This list shows the standard error codes As standard general TC thermocouple errors are Er xx and cooking element specific errors E x are displayed Error code Description Possible cause of error Remedy Er 03 and continuous tone or continuous sensor activation TC turn off after 10 sec Water or cookware on the glass over the touch con...

Page 10: ... power element or error on power board 1 check wiring 2 check filter board 3 replace power board E 8 Incorrect fan speed Error on fan left or right Air exhaust blocked e g by paper Replace Defective fan E 9 Defective temperature sensor on inductor Replace inductor Replace power board ...

Page 11: ...air will rapidly escape CLEANING Your product has a manufacturer s warranty This requires you maintain and care for your product and follow maintenance instructions If you fail to maintain your unit or damage components Lincat may charge you for a warranty repair Please check the website for terms and conditions Isolate from the power supply and allow to cool Do not use a water jet or steam cleane...

Page 12: ...be cleaned in a dishwasher Do not operate the appliance without a filter being fitted otherwise dirt and grease could be drawn into the electronics impairing safe operation and invalidating the warranty All other servicing maintenance and component replacement on this appliance should be carried out by one of our recommended service engineers Please refer to the Service Help Desk number on the fin...

Page 13: ...not diminish your statutory or legal rights The guarantee does not cover Accidental damage misuse or use not in accordance with the manufacturer s instructions Consumable items such as filters glass bulbs slot toaster elements and door seals Damage due to incorrect installation modification unauthorised service work or damage due to scale food debris build up etc The manufacturer disclaims any lia...