CHECK LIST OF ENCLOSURES
Warranty card
Instruction manual
INSTALLATION AND COMMISSIONING
This appliance must be earthed.
An equipotential bonding terminal is provided to allow cross bonding with other
equipment.
If replacing the plug connect the terminals as follows:
Green and Yellow wire Earth E
Blue wire Neutral N
Brown wire Live L1
Black wire Live L2
Grey wire Live L3
Means of isolation with at least 3mm contact separation in all poles must be
incorporated into the fixed wiring of this appliance.
The fixed wiring insulation must be protected by insulated sleeving having a
temperature rating of at least 60
o
C.
Supply cords shall be oil resistant, sheathed flexible cable not lighter than
ordinary polychloroprene or equivalent elastomer sheathed cord (code 60245 IEC
57)
Do not block or restrict the inlet filters on the appliance. Restricted airflow will
result in reduced performance.
Keep means of electrical isolation accessible at all times.
A circuit breaker of type C, of suitable current rating should be fitted.
A Residual Current Device (RCD) of suitable current rating and min 30mA trip
level should be fitted. A short time delay AC-DC sensitive RCD is recommended.