4
TECHNICAL DATA
Model
DF4
DC04
Dimensions
Overall height (mm)
425
Width (mm)
450
Depth (mm)
600
Weight (kg)
29.75kg
29.5kg
Heat Input
Total heat input Natural(Gross)
11.3 kW
Total heat input Propane(Gross)
10.5 kW
Total heat input
– Butane (Gross)
10.5 kW
Connection and Operating Pressures
Gas inlet connection
½” BSPT Male
Supply Pressure - Natural
20mbar
Supply Pressure - Propane
37 \ 50mbar
Supply Pressure - Butane
28-30mbar
Operating Pressures
Natural
16.2 mbar
Propane
35 mbar
Butane
28 mbar
Gas Consumption
Total burner gas rate - Natural
1.08 m
3
h
-1
Total burner gas rate - Propane
0.75 kg h
-1
Total burner gas rate - Butane
0.76 kg h
-1
COMMISSIONING
PREPARATION
Remove all packaging and protective coatings prior to installation.
VENTILATION
The area in which this equipment is to be installed should have sufficient fixed ventilation to
comply with local legislation requirements. It is recommended that a room, or internal
space, be provided with a minimum free area of 4.5cm
2
per kW of total heat input.
OPERATIONAL CHECK
Although all Lincat fryers are functionally checked during manufacture,
commissioning must include a functional check of all controls.