Page 1: ...IS356 ECN3592 User and Installation Instructions DF7 Silverlink 600 Gas Fryer Utensils Direct 01903 823888 www utensilsdirect co uk ...

Page 2: ...OTES ON FRYING 6 7 Frying media Frying times Frying tips Oil capacity OPERATING INSTRUCTIONS 8 10 Initial start up Operating instructions Drainage and cleaning SERVICING 11 13 General routine servicing Component replacement Spares list TROUBLESHOOTING 14 15 SPARES LIST 16 TECHNICAL SPECIFICATION 16 SERVICE 17 Contact information Lincat service department Conditions of guarantee ...

Page 3: ... engineer Whilst in operation parts of the catering equipment will become hot Suitable precautions must be taken to avoid accidental burns therefore the appliance should be positioned to minimise the possibility of accidental touching This appliance is for professional use and shall be operated by qualified personnel CONSEQUENTIAL LOSS Lincat do not accept any responsibility for loss of food produ...

Page 4: ...destals e g model CN7 or stand SLS7 should be used To ensure a free flow of air around and behind the appliance a clear space of at least 20mm must be left at the rear between flue and the wall and 50mm to either side of the appliance or bank of appliances There should be a minimum clearance of 750mm between the top of the appliance and any overlying shelf or ceiling It is recommended that this ap...

Page 5: ...e on page 16 Note An external regulator should be fitted to the fryer if the inlet pressure exceeds 50mbar 3 Use the test point marked OUT Fig 1 B to set the unit to the appropriate burner pressure 4 Adjustment is made via the valve s onboard governor which is situated centrally on the valve Fig 1 C 5 Remove the governor cap and turn the screw clockwise to increase the outlet pressure and anticloc...

Page 6: ...xhausted The next symptom is an unhealthy yellow foam which may appear on the surface and the third and more serious one is that the oil will boil or surge if not changed thereby causing damage Be safe not sorry Keep your oil in good condition and ensure a healthier food product and happier customers Please note also that spent oil will have a lower flash point than new oil and therefore present a...

Page 7: ...getable oil 2 Do not exceed the recommended cooking temperature stated by the supplier 3 Always maintain the oil at the correct level 4 Do not use the Fryer until the oil is at its correct temperature 5 Only use very clean oil and filter it daily 6 Whilst frying carefully remove crumbs and pieces which float on the surface of the oil otherwise this will carbonate and contaminate the oil 6 Keep the...

Page 8: ... the drain pipe and tap are dried thoroughly 4 Run a small quantity of oil across the base of the tank and allow to drain to waste This will remove any residual water and provide the base of the tank with a coating of oil 5 Close the drain valve Note Lids must not be used when cooking is in progress Fig 2 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 1 Thermostat Knob 2 Gas Control Valve 3 Igniter Button 4 Pilo...

Page 9: ... Fig 3 O F F PILOT O N O F F PILOT ON O F F P IL O T ON A B C Standby Once the pilot is lit the appliance may be left on standby by leaving the pilot control knob in the pilot ignition position Fig 3 B When in this position the appliance cannot be operated from the thermostat control knob To re ignite the main burners turn the pilot control knob anti clockwise to the burner position Fig 3 C and op...

Page 10: ...conditions a branded cleanser such as Carb n off makes cleaning easier after an overnight application 1 Isolate the appliance from the gas supply 2 Allow the oil to cool to a maximum 55 o C 3 Drain as per above instructions 4 Wash the tanks and the top surface of the fryer body 5 Clean the drain tube assembly using a tube or flue brush suitable for 15mm tube with the drain valves in the open posit...

Page 11: ... the unit 6 Check that the pilot assembly is burning correctly clean if necessary See Pilot Assembly below 7 Check the spark electrode and thermocouple within the pilot assembly Adjust if necessary 8 Check thermocouple output between interrupter junctions Voltage should be 7mV minimum 9 Ensure that the flue is clear 10 Carryout a gas soundness check 11 Refit facia panel remembering to reconnect pi...

Page 12: ...an then be lowered through the base of the unit by unscrewing the appropriate pilot box from beneath the unit and loosening the pilot pipe at the valve joint Carefully remove the pilot box all pilot components can then be accessed Thermocouple 1 Loosen retaining nut at valve 2 Loosen retaining nut at pilot assembly 3 Disconnect cabling from the interrupter 4 Withdraw thermocouple from pilot assemb...

Page 13: ...cap unscrew the adjuster and remove with the spring 10 Replace spring with Lincat part number SP65 and reassemble 11 Reset burner pressure as per Installation instructions Pressure setting Burner and jet 1 Remove the aeration box top cover at the rear of the burner 2 Undo the pipe union on the burner elbow 3 Remove the burner retaining nut at the front of the burner 4 Withdraw the burner assembly ...

Page 14: ...ry millivolt system consists of a thermopile acting through the gas control via the control thermostat Heat from the pilot flame acting on the thermopile generates a 500 700 mV electrical potential This millivolt system connected to the gas control operates the secondary solenoid that passes gas to the main burners The system is interrupted by the control thermostat as it cycles thereby opening an...

Page 15: ...e stat for open circuit If all of the above are OK the control valve may be faulty Check pilot jet for blockage and clean where necessary Check supply Check thermocouple voltage minium 15mV Is the oil temperature over 220 o C Replace control stat Yes Does the control stat operate on temp rise when set point is low 100 o C No Replace overtemperature stat No Yes Are the connections correct on the ga...

Page 16: ...tat TC39 Interrupted Thermocouple TC20 Thermopile TH99 Control Thermostat TECHNICAL SPECIFICATION Model DF7 Dimensions H W D 425 x 750 x 600 Weight 46kg Inlet connection 1 2 BSP Natural Gas I2H Heat Input Gross 17 0 kW Supply Pressure 20 0 mbar Burner Pressure 15 0 mbar Injector size 2 3mm 740 Gas Rate 1 53 m3 h 1 Propane Gas I3P Heat Input Gross 17 0 kW Supply Pressure 37 mbar Burner Pressure 25 ...

Page 17: ...r persons Note that for safe and efficient operation appliances need regular servicing Please quote both the model and serial numbers from the data plate attached to the unit Give brief details of the service requirement If you know the part number of the part in question please quote this information also Lincat reserve the right to carry out any work under warranty during normal working hours i ...