Thank  you  for  buying  this  Lincat  product,  which  we  hope,  will  give  you  years  of  trouble  free  service.  To 
ensure  you  receive  the  maximum  benefit  from  your  new  Griddle  please  take  the  time  to  read  these 
instructions carefully, following any directions given. 
 
We manufacture over 300 different items of catering equipment and are constantly adding to and improving 
the range. 
If you are thinking of extending your kitchen or renewing a catering appliance in the near future, see our sales 
brochures available from your local distributor or send for one direct from us before you make your decision.

 

 

IMPORTANT

 

Please read this page carefully before using the equipment.

 

 

WARNING

   

It is mandatory that all appliances are installed, commissioned and serviced by a qualified and 
competent person as defined by the regulations in force in the country of installation. 
Failure to comply will invalidate the warranty.

 

 

 

 

 

 

 

Whilst in operation, parts of the catering equipment will become hot.  Suitable precautions must be taken to 
avoid accidental burns; therefore, the appliance should be positioned to minimise the possibility of accidental 
touching.   
 

This appliance is for professional use and should be operated by suitably trained personnel.

 

 

 

CONSEQUENTIAL LOSS

 

 

Lincat Ltd. does not accept any responsibility for loss of food, production time, profit, etc., which may result 
from a breakdown of the equipment 

 
 

MAINTENANCE

 

 

These units must 

not

 be cleaned using a water jet. 

 
Clean units with warm water and detergent - do not use abrasives on outer surfaces of the appliance. 
Using a wire brush to cleanse the griddle plate of carbon deposits is acceptable however eye protection must 
be worn if using a wire brush.  

Summary of Contents for Silverlink 600 GS4

Page 1: ...IS212 ECN3592 Silverlink 600 Gas Griddles GS4 and GS7 User Installation and Servicing Instructions...

Page 2: ...It is mandatory that all appliances are installed commissioned and serviced by a qualified and competent person as defined by the regulations in force in the country of installation Failure to comply...

Page 3: ...Pressure 25 mbar Injector size 0 88 mm Stamp code 100 Gas Rate 0 39 kg h 1 Low rate setting 0 11 kg h 1 1 litre min GS7 Units Dimensions 415 x 600 x 600 Weight 55kg Inlet connection BSP Natural Gas G...

Page 4: ...essure Setting 1 6 Heat Input 2 OPERATING INSTRUCTIONS 8 2 1 Lighting of Appliance 2 2 Shut Down of Appliance 2 3 Preparation for Use 2 4 Care of Griddle Plates 3 SERVICING 9 10 3 1 General Routine Se...

Page 5: ...ioned and serviced by a qualified and competent person as defined by the regulations in force in the country of installation Failure to comply will invalidate the warranty Whilst in operation parts of...

Page 6: ...uld be a minimum clearance of 750mm between the top of the appliance and any overlying shelf or ceiling Where the unit is to be free standing any partitions walls or kitchen furniture in close proximi...

Page 7: ...sure the supply pressure is set to 37mbar and the burner pressure is set to 25mbar Pressure measurement is via the test nipple at the end of the manifold rail Note To obtain the above burner pressures...

Page 8: ...SE 2 3 1 Clean the surface of the griddle with hot soapy water Dry thoroughly and lightly coat in cooking oil 2 3 2 Ensure that the fat drawer is correctly positioned 2 3 3 Light the unit as described...

Page 9: ...MPONENT REPLACEMENT Note When removing the control knob care must be taken not to lose the spring clip 3 2 1 Thermocouple Remove the fat drawer control knobs and fascia panel Remove the rear panel Sli...

Page 10: ...the Lincat reference number followed by a brief description VA11 Multi function valve TC34 Thermocouple BU87 Griddle burner JE35 GS7 N Burner injector natural gas stamp code 160 JE141 GS7 P Burner inj...

Page 11: ...eck gas supply check injector for blockages Check thermocouple connections tighten connections Check thermocouple voltage minimum 5mv replace thermocouple Check thermocouple location Distance from bur...

Page 12: ...oes not cover Accidental breakage or damage Operational misuse wear and tear from normal usage incorrect adjustment or neglect Incorrect installation maintenance modification or unauthorised service w...