16
SPARES LIST.
The following components are listed with the Lincat reference number followed by a brief description.
IG14...................................................... Ignitor Electrode.
IG19………………………………….. Piezo Igniter.
PI25...................................................... Pilot assembly.
TC19.................................................... Thermocouple.
TC20…………………………………. Thermopile.
TH99
………………………………. Control Thermostat.
TH96.................................................... Safety Limit Thermostat
VA20.................................................... Gas Control Valve
Technical Data.
(Models J5 and J10
).
Dimensions
J5 H1060 x W300 x D700
J10 H1060 x W600 x D700
Weight
J5 34.8kg / J10 69.5kg
Inlet connection
1/2 BSP
Natural Gas (G20).
Heat Input (Gross).
11.5 kWh / 22.79 kWh
Supply Pressure
20 mbar
Burner Pressure
16.3 mbar
Injector size
1.90 mm
Gas Rate
1.05 m
3
h
-1
/ 2.35 m
3
h
-1
Propane Gas (G31).
Heat Input (Gross).
11.0 kWh / 22.05 kWh
Supply Pressure
37/50 mbar
Burner Pressure
25 mbar
Injector size
1.35 mm
Gas Rate
0.79 kg h
-1
/ 1.58 kg h
-1