background image

IS384 - ECN3345 

Page 4 

 

SECTION 2 - INSTALLATION 

 

 

2.1 PREPARATION 

 

1.

 

Remove all packaging materials and protective coatings from both the outer body and 

the drip/crumb tray prior to installation. 

2.

 

Remove transportation screws from rear panel of unit (see fig 2). 

3.

 

Do not

 use handle to carry unit. 

 

 

2.2 SITING 

 

1.

 

The appliance must be installed on a non-combustible, level surface in a suitable position 

that is well lit, and positioned so as to prevent accidental touching.  

2.

 

Partitions,  walls,  kitchen  furniture  and  other  materials  less  than  100  mm  from  the 

appliance should be made from non-combustible material.  

3.

 

Ensure there is a free flow of air and adequate ventilation around the appliance, and that 

no vents are blocked. 

4.

 

Silverlink  Vertical  Travel  Salamanders  can  be  either  installed  on  a  counter  or  wall 

mounted using wall mounting brackets (see section 9 - optional accessories). 

 

INSTALLING A WALL MOUNTED UNIT 

 

1.

 

Refer to dimensional drawing (fig 1) and drawing of mounting holes (see fig 2). 

2.

 

Use wall mounting kit supplied by Lincat (optional extra). 

3.

 

Loosen 4 screws in back of unit. 

4.

 

Fit brackets (x 2) to back of unit using existing screws. 

5.

 

Drill 4 holes in wall according to drawing below. 

6.

 

Secure unit to wall. 

 

 

LOOSEN SCREWS (4 OFF)

IN BACK OF UNIT

FIT BRACKETS (2 OFF)

ONTO 4 SCREWS

TRANSPORTATION

SCREWS (2 OFF)

TO BE REMOVED

 

                                                                           (Fig 2) 

 

Mounting hole centres to  

be used when unit is wall mounted. 

 

Summary of Contents for Silverlink 600

Page 1: ...IS384 ECN3345 User and Installation Instructions Silverlink 600 Electric Salamander Grill AS3 and AS4...

Page 2: ...mandatory that all appliances with a power rating over 3kW are installed commissioned and serviced by a qualified and competent person as defined by the regulations in force in the country of installa...

Page 3: ...ply requirements Single phase 12 2 Amps Single phase 18 8 Amps Electricity supply connection Single phase 13A plug 5 Way terminal block Power rating 240V kW 2 8 4 5 Fig 1 Check list of enclosures Plea...

Page 4: ...material 3 Ensure there is a free flow of air and adequate ventilation around the appliance and that no vents are blocked 4 Silverlink Vertical Travel Salamanders can be either installed on a counter...

Page 5: ...ent hood moves freely and remains at set height when released 2 6 USER INSTRUCTION Ensure that the person responsible understands how to safely operate clean and switch off this unit and is made aware...

Page 6: ...ing operations HEAT SHEILD WIRE TRAY GRID WIRE TRAY SUPPORT DRIP CRUMB TRAY WIRE TRAY RUNNER KNURLED KNOBS Fig 3 1 Lift out wire tray grid and drip crumb tray 2 Slide out wire tray support 3 Loosen kn...

Page 7: ...el and serial numbers from the data plate attached to the unit and give brief details of the service requirement Lincat reserve the right to carry out any work under warranty during normal working hou...

Page 8: ...al usage incorrect adjustment or neglect 3 Incorrect installation maintenance modification or unauthorised service work SECTION 9 ACCESSORIES The following accessories are available for your Lincat sa...