F0102,F0103
Variable drive overload. Check the load behaviour. Check the motor parameter
adjustments.
F0200…F0300
Temperature too high. Check cooling, flap, sensor and ambient temperature.
Temperature low. Check the ambient temperature and the heating of the
electrical cabinet.
F0400, F0403
Motor temperature too high or sensor faulty. Check the connection to X12.4.
Phase fault. Check the motor and the wiring
F0500…F0507
Overload, short circuit or dispersion in the ground, motor current or phase
fault. Check the load behaviour and the gradients (P420...P423). Check the
motor and the wiring.
F0700…F0706
DC bus voltage too high or too low. Check the deceleration gradients (P421,
P423) and the connected braking resistor. Check the network voltage. Check
the network voltage, the fuses and the network circuit.
F0801,F0804
Electrical voltage (24V) too high or too low. Check the wiring of the control
terminals
F1100
…F1110
Maximum frequency reached. Check the control signals and adjustments.
Inspect the deceleration gradients (P421, P423) and the connected braking
resistor
F1310
Minimum output current. Check the motor and the wiring.
F1401
Signal of the reference value on the input X12.3 faulty, check the signal.
F1407
Over-intensity at input X12.3, check the signal.
F1408
Over-intensity at input X12.4, check the signal.
A0001…A0004
Variable drive overload. Check the load behaviour. Check the motor and
application parameters.
A0008,A0010
Temperature too high. Check cooling, flap and ambient temperature.
A0080
Once the maximum motor temperature is reached, check the motor and
sensor.
A0100
Network phase failure, check the main fuses and the power cable
A0400
Once the frequency limit is reached; output frequency limited.
A0800
Input signal at X12.3 too low. Increase the value
A1000
Input signal at X12.4 too low. Increase the value
A4000
The voltage of the DC bus has reached the minimum value
POSITIONER FUSES RATINGS
STANDARD POSITIONERS
FU1 (5x20)
FU2 (10x38)
FU3 (5x20)
POSIMATIC PS08
1 A FsT
6 A aM