B-7
OPERATION
37. NEGATIVE BATTERY JUMP START TERMINAL.
38. POSITIVE BATTERY JUMP START TERMINAL.
12V battery jump start feature is standard. Covered output
studs for convenient access, and protection against
accidental impact. These terminals can be used to jump-start
a utility truck with up to 800 cold cranking amps.
39. AIR COMPRESSOR SWITCH AND GAUGES
44
AIR VANTAGE
®
600X-I
Battery Isolator Switch
in locked position
44. BATTERY ISOLATOR
NOTE:
It is also possible to lock service door at the bottom
(Lock is not included).
When rotated clockwise, battery power is supplied to the front
panel to start & run machine. When rotated counter clockwise,
power is cut-off from the front panel and is lockable (lock not
included).
B-7
39A. HOUR METER
39B. AMBER FAULT LIGHT
39C. COMPRESSOR POWER SWITCH
40. AIR COMPRESSOR OUTLET
39D. COMPRESSOR PRESSURE GAUGE
39A
39B
39D
39C
41. 240 VAC IEC SINGLE PHASE RECEPTACLE
42. 120 VAC IEC SINGLE PHASE RECEPTACLE
This is a 120 VAC (IEC 60309 Yellow 2P+Ground) receptacle
that provides 120 VAC single phase auxiliary power. This
receptacle has a 15 amp rating.
43. RESIDUAL CURRENT DEVICE (RCD)
This is a 240 VAC (IEC 60309 Blue 2P+Ground) receptacle
that provides 240 VAC single phase auxiliary power. This
receptacle has a 15 amp rating.
Protects the two 240 VAC auxiliary power receptacles. The
device protects against electric shock if an current leakage
is detected. The RCD is rated for 15 amps and it has 30
milliamp tripping current.