SETUP MENU FEATURES
The Setup Menu gives access to the Setup
Configuration. Stored in the setup configuration are
user parameters that generally only need to be set at
installation. The parameters are grouped as shown in
the following table.
SET-UP FEATURES MENU
(See Figure B.1)
1. To access the set-up menu, press the
Right
and
Left
buttons of the
Main Display
panel simultane-
ously.
Note
that the set-up menu cannot be
accessed if there is a fault (The status
LED
is not
solid green).
Change the value of the blinking parameter by rotat-
ing the
Center
knob.
2. After changing a parameter it is necessary to press
the
Right
hand button to save the new setting.
Pressing the
Left
button will cancel the change.
3. To exit the set-up menu at any time, press the
Right
and
Left
buttons of the Main Display panel
simultaneously. Alternately, 1 minute of inactivity
will also exit the set-up menu.
PARAMETER
DEFINITION
P.1
through
P.99
Unsecured Parameters
(always adjustable)
P.101
through
P.199
Diagnostic Parameters
(always read only)
P.501
through
P.599
Secured Parameters
(only accessible through a p.c.
application)
B-6
OPERATION
B-6
ARC TRACKER™
USER DEFINED PARAMETERS
Parameter
Definition
Exit Setup Menu
P.0
This option is used to exit the setup menu. When P.0 is displayed, press the Left Button to exit
the setup menu.
P.83
Calibration
See
Calibration Specification
section for further details.
P.106
View Ethernet IP Address
Used for viewing the IP address of Ethernet compatible equipment. Press the Right Button to
read the IP Address. Press the Left Button to back out and exit this option. The IP address
cannot be changed using this option.
P.505
Setup Menu Lock
Determines if the setup parameters can be modified by the operator without entering a pass-
code.
No = The operator can change any set menu parameter without first entering the passcode
even if the passcode is non-zero (default).
Yes = The operator must enter the passcode (if the passcode is non-zero) in order to change
any setup menu parameters.
This parameter can only be accessed using Power Wave Manager software.
P.506
Set User Interface Passcode
Prevents unauthorized changes to the equipment. The default passcode is zero which allows
full access. A nonzero passcode will prevent unauthorized changes to setup parameters (if
P.505 = Yes).
This parameter can only be accessed using Power Wave Manager software.
P.509
UI Master Lockout
Locks all user interface controls, preventing the operator from making any changes. This para-
meter can only be accessed using Power Wave Manager software.
Summary of Contents for ARC TRACKER 11724
Page 28: ...F 2 DIMENSION PRINT F 2 ARC TRACKER L15970 A 02 14 48 8 92 11 79...
Page 30: ...03 18 2011 ARC TRACKER P 675 A P 675 A MAIN ASSEMBLY 5 1 3 2 4...
Page 33: ...ARC TRACKER NOTES...
Page 36: ...03 18 2011 ARC TRACKER P 675 D P 675 D Cover Assembly 1A 1A 10 10 3A 3A 5A 5A 5B 5B 3B 3B 2 4...
Page 42: ...03 18 2011 ARC TRACKER P 675 G P 675 G Wraparound Assembly 3 4 5 8 1A 1A 2A 2A 2B 2B...
Page 44: ...ARC TRACKER NOTES...
Page 45: ...NOTES ARC TRACKER...