B-2
INSTALLATION
CV ADAPTER
B-2
4. FOR CODE NUMBERS BELOW 8678, connect
CV Adapter lead 610 to black exciter lead bolted
connection shown in Figure 2 and insulate the con-
nection with tape. Tape unused lead terminal on
lead 610.
FOR CODE NUMBERS ABOVE 8678, tape up ring
terminal on CV Adapter lead 610 and connect
push-on terminal of CV Adapter lead 610 to black
exciter lead on idler control P.C. board that was
connected to brown field lead.
5. Remove existing blue field lead from the center ter-
minal of the Fine Current Adjustment rheostat and
connect it to CV Adapter lead 503 using #10 X 1/4
screw and nut provided. Insulate connection with
tape.
6. Connect CV Adapter lead 602 to the center termi-
nal of the Fine Current Adjustment rheostat.
Connect CV Adapter lead 600 to the end terminal
of the Fine Current Adjustment rheostat that has
an existing lead connected to it.
7. Connect CV Adapter leads “Neg” and “Pos” to the
back of the SA-200 negative and positive output
terminals respectively. Tape these leads to gener-
ator lead bundle for support.
FIGURE 1 – CV Adapter Mounting.
FIGURE 2 – SA-200 with Roof Assembly Removed.
3.
FOR CODE NUMBERS BELOW 8678, unbolt
existing brown field lead from black exciter leads in
the lead bundle and bolt it to CV Adapter lead 509
using #10 x 1/4 bolt and nut provided. Tape up con-
nection and unused lead terminal on lead 509 (see
Figure 2 below).
FOR CODE NUMBERS ABOVE 8678, remove
existing brown field lead from black exciter lead on
the idler control P.C. board and connect the brown
field lead to CV Adapter lead 509 using the exist-
ing push-on terminal. Tape up connection and
unused ring terminal.
Summary of Contents for CV ADAPTER
Page 42: ...E 13 DIAGRAMS E 13 CV ADAPTER CV ADAPTER SCHEMATIC L6922 A ...
Page 43: ......