Automatic Gas Console Specific Errors
Error
Code
Telnet
Description
Possible Resolution
24109 0x100D EX: pac timeout
1) Verify have OCV.
2) Verify preflow gas pressure
3) Verify ASC powered and
discharging.
4) Verify consumables
24110 0x100E EX: remote power off
Check EStop
24111 0x100F EX: Purge in progress
Wait for purge to complete.
24112 0x1010 EX: Invalid purge time
Verify purge time set within xx
and xx seconds.
24113 0x1011 EX: Plasma gas pressure too low to
purge
1) Verify gas input pressures
within limits.
2) Check for gas leaks or
blockage.
24114 0x1012 EX: Shield gas pressure too low to
purge
24115 0x1013 EX: Marking gas pressure too low to
purge
24116 0x1014 EX: Purge gas hoses before first cut.
Command manual gas purge.
24611 0x1203 NRT: Connection Down
Check Ethernet cable
24612 0x1204 RT: Connection down.
Check PS Interconnect cable
25632 0x1600 FU: Validate failed.
25634 0x1602 FU: Invalid image type.