3.16 Software Installation
3.16.1 CutLinc Server
Installation and Commissioning
If the System uses a non-Lincoln Electric HMI (CNC Controller or Industrial
Computer), the CutLinc Server must be installed and commissioned. This is not
required when using a Lincoln Electric provided HMI.
Contact Factory for CutLinc Server Installer.
Manual Start
CutLinc server should automatically start each time the HMI is rebooted; however, to
manually start CutLinc Server, run file:
C: > Program Files > Lincoln Electric > CutLincServer > startCLServer.bat
Discovery for Single-Torch Systems
When any of the System’s Ethernet adapters are replaced (e.g., Processor Engine
PCB in the AGC), the CutLinc server needs to be updated with the new MAC
address. To have the CutLinc server automatically discover the new MAC address,
delete the following file and then reboot the HMI:
C: > local > Users > Public > Public Documents > CutLinc > Discovery > SND.xml
Alternate IP Addresses
When not using DHCP, the following alternate IP addresses will be assigned by
default after the timeout period shown:
Timeout
IP Address
Component
180 seconds 192.168.90.11 Power Supply
10 seconds
192.168.90.12 Automatic Gas Console
~60 seconds 192.168.90.13* HMI
* Must be assigned manually. See instructions below.
The subnet mask is 255.255.255.0.
To manually assign the alternate IP Address for the HMI:
1) On the HMI, navigate to the following:
>
>
>
2) Right-click on the CutLinc adapter ( ) and then choose
Properties.