Electromagnetic Compatibility (EMC) 

11/04 

This machine has been designed in accordance with all relevant directives and standards.  However, it may still generate 
electromagnetic disturbances that can affect other systems like telecommunications (telephone, radio, and television) or 
other safety systems.  These disturbances can cause safety problems in the affected systems.  Read and understand this 
section to eliminate or reduce the amount of electromagnetic disturbance generated by this machine. 
 

This machine has been designed to operate in an industrial area. To operate in a domestic area it is necessary 
to observe particular precautions to eliminate possible electromagnetic disturbances. The operator must install 
and operate this equipment as described in this manual. If any electromagnetic disturbances are detected the 
operator must put in place corrective actions to eliminate these disturbances with, if necessary, assistance from 

Lincoln Electric. 
 
Before installing the machine, the operator must check the work area for any devices that may malfunction because of 
electromagnetic disturbances.  Consider the following. 

  Input and output cables, control cables, and telephone cables that are in or adjacent to the work area and the machine. 

  Radio and/or television transmitters and receivers.  Computers or computer controlled equipment. 

  Safety and control equipment for industrial processes.  Equipment for calibration and measurement. 

  Personal medical devices like pacemakers and hearing aids. 

  Check the electromagnetic immunity for equipment operating in or near the work area.  The operator must be sure that 

all equipment in the area is compatible.  This may require additional protection measures. 

  The dimensions of the work area to consider will depend on the construction of the area and other activities that are 

taking place. 

 
Consider the following guidelines to reduce electromagnetic emissions from the machine. 

  Connect the machine to the input supply according to this manual.  If disturbances occur if may be necessary to take 

additional precautions such as filtering the input supply. 

  The output cables should be kept as short as possible and should be positioned together.  If possible connect the work 

piece to ground in order to reduce the electromagnetic emissions.  The operator must check that connecting the work 
piece to ground does not cause problems or unsafe operating conditions for personnel and equipment. 

  Shielding of cables in the work area can reduce electromagnetic emissions.  This may be necessary for special 

applications. 

 WARNING 

The Class A equipment is not intended for use in residential locations where the electrical power is provided by the public 
low-voltage supply system. There can be potential difficulties in ensuring electromagnetic compatibility in those locations, 
due to conducted as well as radio-frequency disturbances. 

 

 
 

Summary of Contents for handy core

Page 1: ...IM3000 11 2020 REV02 HANDY MIG HANDY CORE OPERATOR S MANUAL ENGLISH Lincoln Electric Bester Sp z o o ul Jana III Sobieskiego 19A 58 260 Bielawa Poland www lincolnelectric eu...

Page 2: ...table below your equipment identification information Model Name Code Serial Number can be found on the machine rating plate Model Name Code Serial number Date Where Purchased ENGLISH INDEX Technical...

Page 3: ...E 20 70A 17 5 Vdc OUTPUT RANGE Welding Current Range Maximum Open Circuit Voltage MIG 45A 80A 29 Vdc CORE 45A 80A 29 Vdc RECOMMENDED INPUT CABLE AND FUSE SIZES Fuse or Circuit Breaker Size Power Lead...

Page 4: ...ode STICK mode After 30 minutes of non working X Fan off The value of efficiency and consumption in idle state have been measured by method and conditions defined in the product standard EN 60974 1 20...

Page 5: ...process gas usage depends on cross sectional area of the nozzle For comonnly used torches Helium 14 24 l min Argon 7 16 l min Notice Excessive flow rates causes turbulence in the gas stream which may...

Page 6: ...rolled equipment Safety and control equipment for industrial processes Equipment for calibration and measurement Personal medical devices like pacemakers and hearing aids Check the electromagnetic imm...

Page 7: ...cordance with local electrical regulations ELECTRICALLY POWERED EQUIPMENT Regularly inspect the input electrode and work clamp cables If any insulation damage exists replace the cable immediately Do n...

Page 8: ...elding gas for the process used and properly operating regulators designed for the gas and pressure used Always keep cylinders in an upright position securely chained to a fixed support Do not move or...

Page 9: ...sible and do not place it on wet ground or in puddles Locate the machine away from radio controlled machinery Normal operation may adversely affect the operation of nearby radio controlled machinery w...

Page 10: ...erminal Make sure that both thumbscrews are tigh 2 For Positive Polarity DC Refer to below Figure To wire for Positive polarity connect the gun cable to the Positive output terminal and the work cable...

Page 11: ...epress the gun trigger switch and feed welding wire through the gun and cable Point the gun away from yourself and others while feeding wire Release the gun trigger after wire appears at the end of th...

Page 12: ...be disconnected from the machine before each maintenance and service After each repair perform proper tests to ensure safety Customer Assistance Policy The business of The Lincoln Electric Company is...

Page 13: ...First read the Part List reading instructions above then refer to the Spare Part manual supplied with the machine that contains a picture descriptive part number cross reference REACh 11 19 Communicat...

Page 14: ...DY MIG 0742 200 936 FLUX NOZZLE GASLESS 0742 200 938 CONTACT TIP 0 6 MM ONLY FOR HANDY MIG 0742 200 937 CONTACT TIP 0 9 MM 2886 162 011 CHIPPING HAMMER BRUSH 0657 229 003 HANDSHIELD 0744 180 047 FILTE...

Reviews: