7
INSTALLATION
PRISM 2400 STATIONARY FAN
INSTALLING THE
STARTER/OVERLOAD
SWITCH
120V ARRANGEMENT
The K1494-2 Starter/Overload Switch is used for manual operation of
the Prism 2400 Stationary Fan. The Starter/Overload Switch is not
required if using a K1669-4 Lamp Kit with Arc Sensor.
Mount the Starter/Overload Switch to a wall in a location convenient
to the operator.
Route a 120VAC, 1ph, 60hz supply cable into the switch compartment
and a power cable between the switch and the Prism 2400 Stationary
diagram located in the diagram section of this manual. Set the
overload to 10.0A.
230V ARRANGEMENT
The K1494-3 Starter/Overload Switch is used for manually operation
Prism 2400 Stationary Fan. The Starter/Overload Switch is not required
if using a K1669-4 Lamp Kit with Arc Sensor. The K1750-1 230V
Conversion Kit adapts the Lamp Kit with Arc Sensor for operation on
230V.
• Mount the Starter/Overload Switch to a wall in a location
convenient to the operator.
• Route a 230VAC, 1ph, 50hz supply cable into the switch
compartment and a power cable between the switch and the
connections per the wiring diagram located in diagram section of
this manual.
Connection changes are necessary to properly operate the fan motor
on 230V/1ph. Refer to the connection diagram on motor nameplate.
.