B - DESCRIPTION
MEC 4
B-5
3 - TORCH COOLING
For cooling the
MEC4
torch in a closed circuit, the following may be used as
cooling liquid:
Either LINCOLN ELECTRIC liquid
Or demineralised water
SPECIAL LINCOLN ELECTRIC LIQUID
NEVER ADD WATER
It is ready for use:
W000010167, 9.6 L drum
W000010168, 19.3 L drum
This product is:
Antifreeze
Anti-algae
Anti-corrosion
Non toxic
Non-inflammable
DEMINERALISED WATER
It must have:
high electrical resistivity
pH close to 7
CAUTION while using water: RISK OF FREEZING
If the ambient temperature is below +5°C (with the equipment halted), the torch
cooling system must be protected from freezing during that period.
To avoid freezing, the cooling unit should be made to run (including overnight and on
weekends), by adding an electric water warming system to the water circuit.
To that end, you can connect the cooling unit and the water warming system to a
mains electricity supply that will not be interrupted overnight or on weekends.
NEVER ADD ANTIFREEZE
The level in the cooling liquid tank must be verified at regular
intervals.