English
English
18
••••
Press the Set Control [11] to select the Display
Configuration. The Check Mark will also change the
position.
A
V
%
Figure 37.
••••
Confirm the select – press the Right Button [12].
••••
Return to the main level of the interface. Instead of
the Welding Parameters Bar is visible the Weld
Score Bar.
125
A
22.5
V
1.2
Steel
ArCO2
21
95%
v
28.6
min
m
5.51
Figure 38.
Note:
If the Set Control [11] is pressed, the Welding
Parameters Bar will be visible for 5 seconds.
Assignment Function to the Right
Button
To the Right Button [12] can assign:
Icon
Description
PF44
PF46
Disabled - OFF (factory
default)
Crater Procedure
Rub-in WFS
Wave Controls
Recall the Program
stored in the User
Memory
-
Note:
To use the assigned functions:
••••
Recall the Program stored in the User Memory
••••
Crater Procedure
••••
Run-in WFS
icons of these functions must be added to the Welding
Parameters Bar [27].
To assign the function to the Right Button [12]:
••••
Access to the Settings and Configuration Menu.
••••
Use the Set Control [11] to highlight the Assigned
Function to the Right Button icon.
?
M
Figure 39.
••••
Press the Set Control [11]. The Assigned Function
Menu is shown on the display.
OFF
Figure 40.