User interface type
Determines how the user interface works:
•
"Feeder" (factory default) – UI works as Feeder.
•
"STICK/TIG" – Dedicated to work UI with a welding power source (without
Wire feeder). UI allows to set the programs for welding SMAW and GTAW
process.
Note:
"STICK / TIG" allows to work with an analog wire feeder also. In this
case, additional programs are avaliable for welding GMAW process in non-
synergic mode.
•
"Parallel" – UI works as a remote control. Parallel may be used only in
parallel with the main panel, which can be set to the "FEEDER" or "STICK /
TIG".
Note:
Selecting the UI type makes restart of system.
Note:
Back to the factory setting forces Feeder type.
P.99
Show Test Modes?
Uses for calibration and tests.
••••
"No" (factory default) = Turned off;
••••
"Yes" = Allows to selection test modes.
Note:
After the device has been restarted the P.99 is "NO".
Table 12. List of Secured Parameters accessible through Power Wave Manager only
P.003
Display Options
Enables select between one of the four Display Configurations:
•
"True Energy" = Energy is displayed, along with time in HH:MM:SS format.
•
"Weld Score" = The accumulative weld score result is shown.
•
"Big Meters" (factory default) = After 5 seconds of inactivity, only Welding
Current and Voltage is shown on the display, the Welding Parameters Bar
[27] is invisible. To activate the Welding Parameters Bar [27], press the Set
Control [11].
•
"Standard" = On the Display is shown preset information during and after a
weld.
P.501
Encoder Lockout
Locks one or both of the upper Controls ([9] and [10]), preventing the operator
from changing wire feed speed, amps, volts or trim. The function of each upper
Control depends on the selected weld mode.
•
"Both Encoders Unlocked" (factory default) = The Left [9] and the Right
Control is unlocked.
•
"Both Encoders Locked" = The Left [9] and the Right Control is locked.
•
"Right Encoder Locked" = The Right Control [10] is locked.
•
"Left Encoder Locked" = The Left Control [9] is locked.
Note:
This parameter can only be accessed using PowerWave Manager
software.
P.502
Memory Change
Lockout
(PF46 only)
Determines if the memories can be overwritten with new contents.
•
"No" (factory default)= Memories can be saved and limits can be configured.
•
"Yes" = Memories cannot be changed - saving is prohibited and limits
cannot be re-configured.
Note:
This parameter can only be accessed using PowerWave Manager
software.
P.503
Memory Button Disable
(PF46 only)
Disables the specified memory button(s). When a memory is disabled, welding
procedures cannot be restored from or saved to that memory. If an attempt is
made to save or restore a disabled memory, a message will be displayed on
the lower display indicating the memory number is disabled. In multi-head
systems, this parameter disables the same memory buttons on both feed
heads.
Note:
This parameter can only be accessed using PowerWave Manager
software.