English
English
26
P.504
Mode Select Panel Lock
Selects between several Mode Select Panel lockout preferences. When a
Mode Select Panel selection is locked and an attempt is made to change that
parameter, a message will be displayed on the display indicating the parameter
is locked.
••••
"All MSP Options Unlocked" (factory default) = All adjustable parameters on
the Mode Select Panel are unlocked.
••••
"All MSP Options Locked" = All Controls and buttons on the Mode Select
Panel are locked.
••••
"Start & End Options Locked" = The Start and End parameters on the Mode
Select Panel are locked, all others are unlocked.
••••
"Weld Mode Option Locked" = The weld mode cannot be changed from the
Mode Select Panel, all others Mode Select Panel settings are unlocked.
••••
"Wave Control Options Locked" = The Wave Control parameters on the
Mode Select Panel are locked, all others are unlocked.
••••
"Start, End, Wave Options Locked" = The Start, End and Wave Control
parameters on the Mode Select Panel are locked, all others are unlocked.
••••
"Start, End, Mode Options Locked" = The Start, End and Weld Mode Select
parameters on the Mode Select Panel are locked, all others are unlocked.
Note:
This parameter can only be accessed using PowerWave Manager
software.
P.505
Setup Menu Lock
Determines if the setup parameters can be modified by the operator without
entering a passcode.
••••
"No" (factory default)= The operator can change any set menu parameter
without first entering the passcode even if the passcode is non-zero (0000).
••••
"Yes" = The operator must enter the passcode (if the passcode is non-zero)
in order to change any setup menu parameters.
Note:
This parameter can only be accessed using PowerWave Manager
software.
P.506
Set User Interface
Passcode
Prevents unauthorized changes to the equipment. The default passcode is
0000 which allows full access. A nonzero passcode will prevent unauthorized:
Changes to memory limits, saving to memory (if P.502 = Yes).
Changes to setup parameters (if P.505 = Yes).
Note:
This parameter can only be accessed using PowerWave Manager
software.
P.507
Clear All Memories
Allows the operator to quickly set all memories to the default weld mode and
welding parameters.
••••
"No" (factory default)
••••
"Yes" = Set all memories to the default weld mode and welding parameters.
Note:
This parameter can only be accessed using PowerWave Manager
software.
P.509
UI Master Lockout
Locks all user interface controls, preventing the operator from making any
changes.
Note:
This parameter can only be accessed using PowerWave Manager
software.