English
English
47
Error’s Message
Table 23. Interface Components
36
DESCRIPTION:
Thermal Overload
53
54
Figure 100.
Interface description
53. Error Code
54. Error description.
The following is a partial list of possible error codes. For a complete listing contact with Local Lincoln Authorized Field
Service.
Table 24. Exemplary Error Codes.
Error Code Symptoms
Possible Cause
Recommended Course of Action
6
Power source is not
connected.
The User Interface cannot seem
to communicate with the Power
Source.
•
Check cable connections between the
power source and the user interface.
36
The machine has shut
down because it has
overheated.
System detected a temperature
level beyond the normal system
operating limit.
•
Be sure process does not exceed duty
cycle limit of the machine.
•
Check the setup for proper air flow
around and through the system.
•
Check that the system has been
properly maintained, including removal
of accumulated dust and dirt from the
intake and outlet louvers.
81
Motor overload, long
term.
The wire drive motor has
overheated. Check that the
electrode slides easily through
the gun and cable.
•
Remove tight bends from the gun and
cable.
•
Check that the spindle brake is not too
tight.
•
Verify the adequacy of the electrode to
the welding process.
•
Verify a high quality electrode is being
used.
•
Check drive rolls alignment and gears.
•
Wait for the error to reset and the motor
to cool (approximately 1 minute).
WARNING
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact
your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.