Parameter Name
and
Description Range
P.18 Wire
Drive
Gear
Ratio
This option selects the Wire Drive Gear Ratio that will be used. The possible
selectable values are read from the Wire Drive on startup. For semi-automatic
systems, if the feedhead board has dip switches, this option does not appear in
the menu. Gear ratio can be selected using the dip switches.
On dual-head PF84 Feeders, a different setting can be used for each head.
The operator will be prompted to select which head to edit before the setting
can be changed.
Note: Changing this value will cause the system to reset.
P.19 Wire
Drive
Direction
Used to select the wire drive “Forward” direction for single wire drive feeders. If
the wire drive is reassembled to the left side, the direction must change.
A ->B = Wire drive assembled on the right hand side (default)
B -> A = Wire drive assembled on the left hand.
A ->B
B -> A
P.20
Display Trim as Volts Option
This option determines how trim is displayed.
False = The trim is displayed in the format defined in the weld set (default).
True = All trim values are displayed as a voltage.
Note: This option may not be available on all machines. The power source
must support this functionality, or this option will not appear in the menu.
False, True
P.22
Arc Start/Loss Error Time
This option can be used to optionally shut off output if an arc is not established,
or is lost for a specified amount of time.
Error 269 will be displayed if the machine times out. If the value is set to OFF,
machine output will not be turned off if an arc is not established nor will output
be turned off if an arc is lost. The trigger can be used to hot feed the wire
(default). If a value is set, the machine output will shut off if an arc is not
established within the specified amount of time after the trigger is pulled or if
the trigger remains pulled after an arc is lost. This is disabled while welding in
Stick, TIG or Gouge. To prevent nuisance errors, set Arc Start/Loss Error Time
to an appropriate value after considering all welding parameters (run-in wire
feed speed, weld wire feed speed, electrical stick out, etc). To prevent
subsequent changes to Arc Start/Loss Error Time, the setup menu should be
locked out by setting Preference Lock = Yes using the Power Wave
Manager software.
P.24 Push
Pull
Type
Allows operator to choose the Prince option if welding with a Prince Push Pull
gun. This gun requires unique settings to run at the correct WFS.
Default
Price
P.27 Language
Select
Selects which language will be displayed on the User Interface.
English (Default)
Italiano
Deutsch
Francais
Polski
Espanol
English,
Italiano,
Deutsch,
Francais,
Polski,
Espanol
P.28
Display Workpoint as Amps Option
This option determines how workpoint is displayed.
False = The workpoint is displayed in the format defined in the weld set
(default).
True = All workpoint values are displayed as an amperage.
Note: This option may not be available on all machines. The power source
must support this functionality, or this option will not appear in the menu.
False, True