Parameter Name
and
Description Range
P.99
Show Test Modes
Most power sources contain weld modes used for calibration and test
purposes. By default, the machine does not include test weld modes in the list
of weld modes that are available to the operator. To manually select a test
weld mode, set this option to "Yes". When the power source is turned off and
back on again, the test modes will no longer appear in the mode list. Test weld
modes typically require the machine output to be con-nected to a grid load and
cannot be used for welding.
P.100 View
Diagnostics
Diagnostics are only used for servicing or troubleshooting the Power Wave
system. Select "Yes" to access the diagnostic options in the menu. Additional
parameters will now appear in the setup menu (P.101, P.102, etc).
P.101 View
Event
Logs
Used for viewing all the system event logs.
Press the Right Button to enter the option. Rotate Control Knob to select the
desired event log to read. Press the Right Button again to enter the selected
log. Rotating the Control Knob will scroll through the event log, displaying the
log index number, event code and some other data. Press the Left Button to
back out to select another log.
Press the Left Button again to exit this option.
P.102 View
Fatal
Logs
Used for viewing all the system fatal logs.
Press the Right Button to enter the option. Rotate Control Knob to select the
desired fatal log to read. Press the Right Button again to enter that log.
Rotating the Control Knob will scroll through the log, displaying the log index
number and fatal code. Press the Left Button to back out to select another log.
Press the Left Button again to exit this option.
P.103
View Software Version Information
Used for viewing the software versions for each board in the system.
Press the Right Button to enter the option. Rotate Control Knob to select the
desired board to read. Press the Right Button again to read the firmware
version. Press the Left Button to back out to select another board. Rotate the
Control Knob to select another board, or Press the Left Button to exit this
option.
P.104
View Hardware Version Information
Used for viewing the hardware version for each board in the system. Press the
Right Button to enter the option.
Rotate Control Knob to select the desired board to read. Press the Right
Button again to read the hardware version. Press the Left Button to back out to
select another board. Press the Left Button again to exit this option
P.105
View Welding Software Information
Used for viewing the Weld Set in the Power Source.
Press the Right Button to read the Weld Set version.
Press the Left Button to back out and exit this option
P.106 View
Ethernet
IP
Address
Used for viewing the IP address of Ethernet compatible equipment.
Press the Right Button to read the IP Address.
Press the Left Button to back out and exit this option. The IP address cannot
be changed using this option.
P.107
View Power Source Protocol
Used for viewing the type of power source the feeder is connected to.
Press the Right Button to identify the power source as either LincNet or
ArcLink.
Press the Left Button to back out and exit this option.
P.500 View
Lockout
Parameters
Originally used to prevent inadvertent changes of secure setup parameters,
P.500 was previously used as a gateway to these parameters. Presently, this
option does not exist in any setup menu.
P.501 Encoder
Lockout
Locks one or both of the upper knobs (encoders), preventing the operator from
changing wire feed speed, amps, volts or trim. The function of each upper knob
depends on the selected weld mode. When a constant current weld mode is
selected (e.g. Stick, TIG, Gouge), the upper right knob will always function as
an on/off switch.
This parameter can only be accessed using Power Wave Manager software.