40
Parameter Name
and
Description Range
P.502
Memory Change Lockout
Determines if the memories can be overwritten with new contents.
Unlocked = Memories can be saved and limits can be configured (default).
Fully Locked = Memories cannot be changed - saving is prohibited and limits
cannot be reconfigured. Allow Saving Within Limits = Allows saving to memory
when limits are enabled. Only the nominal value is saved and only to the
selected memory.
This parameter can only be accessed using Power Wave Manager software.
No, Yes
P.503 Memory
Button
Disable
Disables the specified memory button(s). When a memory is disabled, welding
procedures cannot be restored from or saved to that memory. If an attempt is
made to save or restore a disabled memory, a message will be displayed on
the lower display indicating the memory number is disabled. In multi-head
systems, this parameter disables the same memory buttons on both feed
heads.
This parameter can only be accessed using Power Wave Manager software.
P.504
Mode Select Panel Lock
Selects between several Mode Select Panel lockout preferences. When a
Mode Select Panel selection is locked and an attempt is made to change that
parameter, a message will be displayed on the lower display indicating the
parameter is locked.
All MSP Options Unlocked = All adjustable parameters on the Mode
Select Panel are unlocked.
All MSP Options Locked = All knobs and buttons on the Mode Select
Panel are locked.
Start & End Options Locked = The Start and End parameters on the Mode
Select Panel are locked, all others are unlocked.
Weld Mode Option Locked = The weld mode cannot be changed from the
Mode Select Panel, all others Mode Select Panel settings are unlocked.
Wave Control Options Locked = The Wave Control parameters on the
Mode Select Panel are locked, all others are unlocked.
Start, End, Wave Options Locked = The Start, End and Wave Control
parameters on the Mode Select Panel are locked, all others are unlocked.
Start, End, Mode Options Locked = The Start, End and Weld Mode Select
parameters on the Mode Select Panel are locked, all others are unlocked.
This parameter can only be accessed using Power Wave Manager software.
All MSP Options
Unlocked
All MSP Options
Locked
Start & End
Options Locked
Weld Mode Option
Locked
Wave Control
Options Locked
Start, End Wave
Options Locked
Start, End, Mode
Options Locked
P.505 Setup
Menu
Lock
Determines if the setup parameters can be modified by the operator without
entering a passcode.
No = The operator can change any set menu parameter without first
entering the passcode even if the passcode is non-zero (default).
Yes = The operator must enter the passcode (if the passcode is non-zero)
in order to change any setup menu parameters.
This parameter can only be accessed using Power Wave Manager.
P.506
Set User Interface Passcode
Prevents unauthorized changes to the equipment. The default passcode is
zero which allows full access. A nonzero passcode will prevent unauthorized:
changes to memory limits, saving to memory (if P.502 = Yes), changes to
setup parameters (if P.505 = Yes).
If someone repeatedly enters an invalid passcode 5 times in a row, the
passcode will be automatically set to 9999, which is an invalid code and the
interface can no longer be unlocked. PWManager is required to reset the
passcode or unlock the machine.
This parameter can only be accessed using Power Wave Manager software.
P.507 UI
Clear
All Memories
Allows the operator to quickly set all memories to the default weld mode and
welding parameters.
This parameter can only be accessed using Power Wave Manager soft-ware
P.509 UI
Master
Lockout
Locks all user interface controls, preventing the operator from making any
changes.
This parameter can only be accessed using Power Wave Manager soft-ware