![background image](http://html.mh-extra.com/html/lincoln-electric/power-mig-11521/power-mig-11521_service-manual_1918392061.webp)
This is a typical DC output voltage
waveform generated from a properly
operating machine. Note that each
vertical division represents 10 volts
and that each horizontal division rep-
resents 5 milliseconds in time. The
machine was loaded with a resistance
grid bank.
Note: Scope probes connected at
machine output terminals: (+)
probe to electrode, (-) probe to
work.
SCOPE SETTINGS
Volts/Div.....................10V/Div.
Horizontal Sweep .....5 ms/Div.
Coupling.............................DC
Trigger.........................Internal
TYPICAL OUTPUT VOLTAGE WAVEFORM - MACHINE LOADED
(MAX TAP “G”)
0 volts
5ms
10.0V
TROUBLESHOOTING AND REPAIR
F-23
F-23
Power MIG® 215XT
MACHINE LOADED TO 200 AMPS AT 22 VDC
Return