C-4
ACCESSORIES
STEP 10 – Connect Bypass Control wire to 2nd lower port on
Lincoln Smart Connect 4DD module (Module #1, Port “X2”)
STEP 11 – Connect Diagnostic/Warning Light to 3rd lower port on
Lincoln Smart Connect 4DD module using a 10m (33 ft) long green
cable (Module #2, Port “X1”).
STEP 12 – Connect Smoke Detector to 4th lower port on Lincoln
Smart Connect 4DD module using a 20m (65.5 ft) long green
cable (Module #2, Port “X2”). Dual fan units have two smoke
detectors. Connect a splitter to Module #2, Port "X2", then
connect both smoke detectors to the splitter.
STEP 13 (top fan mount units only) – Connect Lincoln
Smart Connect 2DD module on top of unit to inlet
damper’s 2DD module as shown using a 10m (33 ft)
long green cable. If the unit has a 2nd supply/inlet
damper, connect 1st damper’s 2DD module to 2nd damper’s
2DD module using a 3m (10 ft) long green cable.
NOTICE: Last damper in string must have the termination
module attached to the 2DD module.
STEP 14 (remote fan units only) – Connect Lincoln Smart Connect
4DD module above unit’s rear compressed air tank to exhaust
damper’s 2DD module on top of unit using a 3m (10 ft) long green
cable. If unit has a 2nd exhaust damper, connect 1st damper’s
2DD module to 2nd damper’s 2DD module using a 3m (10ft) long
green cable.
STEP 15 (remote fan units only) – Connect last exhaust damper’s
2DD module to supply/inlet damper’s 2DD module using a 10m
(33 ft) long green cable. If unit has a 2nd supply/inlet damper,
connect 1st damper’s 2DD module to 2nd damper’s 2DD module
using a 3m (10ft) long green cable.
NOTICE: Last damper in string must have the termination module
attached to the 2DD module.
Module #2
Port X2
Module #2
Port X1
Module #1
Port X2
Pre-Wired
Pre-Wired
Pre-Wired
Pre-Wired
Step 14b
Green Cable
3m (10 ft) Long
Step 14a
Green Cable
3m (10 ft) Long
Green Cable
10m (33 ft) Long
Step 15b
Green Cable
10m (33 ft) Long
Step 15a
Termination
Module
L17587-18 shown
Termination
Module
PRISM
®
Dual Fan Units Only:
Add splitter to this
port for two smoke
detectors
Summary of Contents for Prism 4
Page 31: ...A 23 INSTALLATION d Reclasp filter handles FIGURE A 15 PRISM ...
Page 77: ......