17
Diagrams
Engine Welders/LN-25 across the Arc Connection Diagram with Optional K857
Remote Control
WARNING
Do not operate with panels open.
Disconnect NEGATIVE (-) Battery lead before servicing.
Do not touch electrically live parts.
WARNING
Keep guards in place
Keep away from moving parts.
Only qualified personnel should install, use or service this equipment
A. WELDING CABLES MUST BE OF PROPER CAPACITY FOR THE CURRENT AND DUTY CYCLE OF IMMEDIATE
AND FUTURE APPLICATIONS. SEE OPERATING MANUAL.
B. CONNECT WELDING CABLES TO OUTPUT STUDS FOR DESIRED POLARITY. POSITION THE WIRE FEEDER
VOLTMETER SWITCH TO MATCH THE POLARITY OF THE ELECTRODE CABLE.
C. PLACE THE MODE SWITCH IN THE “CV-WIRE” POSITION.
D. PLACE THE WELDING TERMINALS SWITCH IN THE “WELD TERMINALS ON” POSITION.
E. PLACE IDLER SWITCH IN “AUTO” OR “HIGH” IDLE POSITION AS DESIRED.
S24787-1
TO WORK
ELECTRODE CABLE
TO WORK
WORK CLIP LEAD
OPTIONAL K857