TEST DESCRIPTION
The rocker is the part of the welding generator that supports and positions the 4 sets of
brushes. Its position can be adjusted to fine tune the weld output and influence the weld
characteristics.
IMPORTANT:
The rocker is set at the factory for the best overall performance and long
generator and brush life. Altering this adjustment is normally not recom-
mended unless one or more of the welding generator components affect-
ing this setting have been replaced. In very unusual situations, very
small adjustments of the rocker may be beneficial if the machine is oper-
ating within the specified limits, but the arc characteristics are unsatisfac-
tory for the desired application.
CAUTION:
Improper rocker adjustment can result in poor performance, reduced brush
life and damage to the welding generator. This adjustment should only be
attempted by an experienced professional.
MATERIALS NEEDED
Resistive load bank, capable of absorbing at least a 500 Amp load.
Volt meter
Ammeter, able to read at least 500 Amps
Miscellaneous hand tools
Drill with 1/8” bit
Tachometer or frequency meter.
ROCKER ADJUSTMENT PROCEDURE
TROUBLESHOOTING AND REPAIR
F-55
F-55
SAE-400 SEVERE DUTY
Return to Section
T
OC
Return to Section
T
OC
Return to Section
T
OC
Return to Section
T
OC
Return to Master
T
OC
Return to Master
T
OC
Return to Master
T
OC
Return to Master
T
OC
WARNING