A-1
A-1
INSTALLATION
SP-135 PLUS
Fuse or
Output Mode
Input Voltage
Breaker Size
Input Amps
Extension Cord
Three Conductor
#14 AWG
RATED
115V/60Hz
20 Amp
20
(2.1 mm
2
) or Larger
for up to
25 feet (7.6m)
Three Conductor
#12 AWG
MAXIMUM
115V/60Hz
25 Amp
25
(3.3 mm
2
) or Larger
for up to
50 feet (15.2 m)
TECHNICAL SPECIFICATIONS
–
SP-135 PLUS
INPUT
–
SINGLE PHASE ONLY
RATED OUTPUT
OUTPUT
RECOMMENDED INPUT CABLE AND FUSE SIZES
Height
Width
Depth
Weight
12.0 in
9.75 in
16.5 in
54 Ibs
305 mm
248 mm
419 mm
24.3 kg
PHYSICAL DIMENSIONS
Standard Voltage/Frequency
Input Current
115V/60Hz
20 Amps - Rated Output
115V/60Hz
25 Amps - Maximum Output
115V/60Hz
15 Amps - CSA Rated output
Duty Cycle
Amps
Volts at Rated Amperes
20% Duty Cycle
–
Rated DC Output
90
18
Welding Current Range (Continuous)
Maximum Open Circuit Voltage
Auxiliary Power
Rated DC Output: 25
–
135 Amps
28
N/A