English 19 English
CAUSES
SOLUTIONS
DISPLAY OF THE MESSAGE
E01-ond
THE MAXIMUM STRIKING CURRENT OF THE
POWER SOURCE WAS EXCEEDED
PRESS THE OK BUTTON TO CLEAR THE FAULT. IF THE
PROBLEM PERSISTS, CALL CUSTOMER SUPPORT
DISPLAY OF THE MESSAGE
E02
inu
POOR RECOGNITION OF THE SOURCE OF POWER
– ONLY AT START-UP –.
Make sure that the ribbon cable between the inverter's main
card and the cycle card is properly connected.
Connectors in fault
DISPLAY OF THE MESSAGE
E07
400
Inappropriate main voltage
Make sure that the main voltage is in the +/- 20%
acceptable range of primary power supply of the power
source.
DISPLAY OF THE MESSAGE
E24
SEn
Temperature sensor in fault
MAKE SURE THAT CONNECTOR B9 IS PROPERLY
CONNECTED TO THE CYCLE CARD (IF NOT,
TEMPERATURE MEASUREMENT IS NOT PERFORMED)
THE TEMPERATURE SENSOR IS OUT OF ORDER. CALL
CUSTOMER SUPPORT
DISPLAY OF THE MESSAGE
E25
-C
Power source overheating
Let the generator cool down
The fault disappears by itself after several minutes
Ventilation
MAKE SURE THAT THE INVERTER FAN WORKS.
DISPLAY OF THE MESSAGE
E33
-
MEM-LIM
This message indicates that the memory is no longer operational
Malfunctioning during saving of memory
CALL CUSTOMER SERVICE.
DISPLAY OF THE MESSAGE
E43
brd
Electronic board in default
CALL CUSTOMER SERVICE.
DISPLAY OF THE MESSAGE
E50
H2o
Cooler unit in default
MAKE SURE THAT COOLER UNIT IS WELL PLUGGED.
CHECK COOLER UNIT (TRANSFORMER,
WATERPUMP,...)
IF NO COOLER UNIT IS USED, DESACTIVATE
PARAMETER IN
DISPLAY OF THE MESSAGE
E63
IMO
Mechanical problem
PRESSURE ROLLER IS TOO TIGHT.
WIRE FEED HOSE IS CLOGGED WITH DIRT.
THE LOCK OF THE WIRE FEED SPOOL AXLE IS TOO
TIGHT.
DISPLAY OF THE MESSAGE
E65-Mot
Defective connectors
Mechanical problem
Power supply
Check the connection of the encoder ribbon cable to the
wire feeder's motor.
MAKE SURE THAT THE WIRE FEEDER ASSEMBLY IS
NOT BLOCKED.
Check the connection of the motor's power supply.
Check F2 (6A) on the auxiliary power card.
DISPLAY OF THE MESSAGE
E-71-PRO-DIA-MET-GAS
Troubleshooting procedure
Servicing of electrical equipment must be performed by qualified personnel only.
GENERATOR IS ON WHILE THE FRONT PANEL IS OFF
Power
s
upply
CHECK THE MAINS SUPPLY (TO EACH PHASE)