English 20 English
HMI selector PROCESS-DIAMETER-METAL-GAS in
default
Turn selector to unlock, after call customer service if always
in
default
DISPLAY OF THE MESSAGE
StE
PUL
Inverter not well recognized
Call Customer Service
DISPLAY OF THE MESSAGE
I-A-MAHX
Maximum current of power source reached
Decrease wire speed or arc voltage
DISPLAY OF THE MESSAGE
bPX-on
Message indicating that
or
is kept depressed
at unexpected times
Push
to unlock, after call customer service if always in
défault
DISPLAY OF THE MESSAGE
SPEXXX
Wire feeding is always activated involuntarily
Check the wire feeding button isn’t blocked
Check the connection of this button and electronic board
DISPLAY OF THE MESSAGE
LOA DPC
UPDATE software by PC is activated involuntarily
Stop and start the power source, after call customer service
if always in
default
TRIGGER FAULT
This message is generated when the trigger is pulled at
a time when it can accidentally cause starting a cycle.
Trigger pulled before the power source is turned on or
during a reset due to a fault.
NO WELDING POWER - NO ERROR MESSAGE
Power cable not connected
Check the connection of the ground strip and the torch
Power source failure
IN COATED ELECTRODE MODE, CHECK FOR VOLTAGE
BETWEEN THE WELDING TERMINALS AT THE FRONT
OF THE GENERATOR. IF NO VOLTAGE, CALL
CUSTOMER SUPPORT.
WELDING QUALITY
Wrong calibration
Check the fine setting parameter (RFP = 0)
Change of torch and/or ground strip or workpiece
Perform re-calibration.(Verify proper electrical contact at the
welding circuit).
Unstable or fluctuating welding
Make sure that the sequencer is not activated. Check the
Hot Start and the down-slope.
Unstable or fluctuating welding
Select the manual mode. The limitation is imposed by
synergy compatibility rules.
Limited range of adjustment settings
IF USING RC JOB MAKE SURE YOU HAVE NOT
ACTIVATED THE PASSWORD-OPERATED SETTING
LIMITATION
Poor power source power supply
Check proper connection of the three power supply phases.
OTHER
Wire stuck in the molten pool or at the contact tube
OPTIMISE THE ARC EXTINCTION PARAMETERS:PR
SPRAY AND POST RETRACT
Display of the
triG
message when turning the power on.
THE
TTRIG
MESSAGE IS DISPLAYED IF THE TRIGGER
IS ACTIVATED BEFORE SWITCHING ON THE WELDING
SET
If the problem persists, you may reset the parameters to factory defaults. For this purpose, with the welding unit
turned off, select the Setup position at the front panel selector, press
and keep it depressed while turning on
the generator.
PLEASE NOTE
Consider recording your work parameters first, because this operation will erase all the programmes saved in
memory. If RESETTING to factory values does not solve the problem, call Customer Support.