Cooling System Specifications
Part Number ..................................................... BK300275
Discharge pressure .......................................... 150 psi (10.2 bar)
Flow rate .......................................................... 2.1 gal/min (7.9 liters/min)
Coolant fluid ..................................................... Propylene glycol solution
Coolant tank capacity ....................................... 3.2 gal (12 liters)
Weight .............................................................. 141 lbs (64 kg) (without coolant)
36.0" [914]
23.0" [584]
15.8" [401]