Postflow Gas Hose
1. Connect one end of the postflow hose to the postflow outlet on the rear of the
MGC. Note that the postflow hose fittings have left hand threads.
2. Connect the other end of the postflow hose to the postflow inlet on the 5-gang
manifold.
Plasma Gas Hose
1. Connect one end of the plasma hose to the plasma outlet on the rear of the
MGC.
2. Connect the other end of the plasma hose to the plasma inlet on the 2-gang
manifold.
Shield Gas Hose
1. Connect one end of the shield hose to the shield outlet on the rear of the
MGC.
2. Connect the other end of the shield hose to the shield inlet on the 5-gang
manifold.
Preflow Gas Hose
1. Connect one end of the preflow hose to the preflow outlet on the rear of the
MGC. Note that the preflow hose fittings have left hand threads.
2. Connect the other end of the preflow hose to the preflow inlet on the 5-gang
manifold.
5-Gang Manifold Control Cable
1. Connect the 5-gang manifold control cable plug marked P15 to the 5-gang
manifold as shown.
2. Connect the 5-gang manifold control cable plug labeled P12 to the connector
labeled P12 on the rear of the power supply.
2-Gang Manifold Control Cable
1. Connect the 2-gang manifold control cable plug marked P18 to the 2-gang
manifold as shown.
2. Connect the 2-gang manifold control cable plug labeled P13 to the connector
labeled P13 on the rear of the power supply.